Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1994
Principal Product Residential interior wooden doors
NAICS n/a
SIC 2431 - Millwork
Sales $10,000,000-$50,000,000
# of Employees 56
Plant Area (Sq.Ft.) 78,000
Annual Production 1,100,000 Pieces
Production Hrs. Annual 4,420
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $30,531 533,705 kWh $0.06
Natural Gas $12,309 2,132 MMBtu $5.77
TOTAL ENERGY COSTS $42,840
RECOMMENDED SAVINGS* $189,045 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $121,441
#|Description Savings
Cost
Status Electricity Usage Natural Gas Solid Waste (non-haz) Electricity Usage Natural Gas Solid Waste (non-haz)
$ kWh $ MMBtu $ lb
01: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$5,297
Cost:
$17,400
- - $5,297 2,025 - - -
-
kWh
$5,297
2,025
MMBtu
-
-
lb
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,314
Cost:
$490
$2,314 41,325 - - - - $2,314
41,325
kWh
-
-
MMBtu
-
-
lb
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$952
Cost:
$300
$952 16,999 - - - - $952
16,999
kWh
-
-
MMBtu
-
-
lb
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$624
Cost:
$440
$624 11,137 - - - - $624
11,137
kWh
-
-
MMBtu
-
-
lb
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$261
Cost:
-
$261 4,689 - - - - $261
4,689
kWh
-
-
MMBtu
-
-
lb
06: 3.1182 MAKE A NEW BY-PRODUCT Savings:
$118,866
Cost:
$206,400
- - - - $118,866 1,755,000 -
-
kWh
-
-
MMBtu
$118,866
1,755,000
lb
07: 3.1162 USE LESS WASTEFUL PACKAGING Savings:
$35,354
Cost:
$65,000
- - - - $35,354 729,000 -
-
kWh
-
-
MMBtu
$35,354
729,000
lb
08: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS Savings:
$14,584
Cost:
$13,200
- - - - $14,584 14,300 -
-
kWh
-
-
MMBtu
$14,584
14,300
lb
09: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS Savings:
$5,860
Cost:
-
- - - - $5,860 1,823,000 -
-
kWh
-
-
MMBtu
$5,860
1,823,000
lb
10: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER Savings:
$4,933
Cost:
$8,480
- - - - $4,933 214,500 -
-
kWh
-
-
MMBtu
$4,933
214,500
lb
TOTAL RECOMMENDED Savings:
$189,045
Cost:
$311,710
$4,151 74,150 $5,297 2,025 $179,597 4,535,800 $4,151
74,150
kWh
$5,297
2,025
MMBtu
$179,597
4,535,800
lb
TOTAL IMPLEMENTED Savings:
$121,441
Cost:
$206,890
$2,575 46,014 - - $118,866 1,755,000 $2,575
46,014
kWh
-
-
MMBtu
$118,866
1,755,000
lb
Savings
Cost
$ kWh $ MMBtu $ lb
Electricity Usage Natural Gas Solid Waste (non-haz) Electricity Usage Natural Gas Solid Waste (non-haz)