Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 1996 |
Principal Product | Hydraulic pumps |
NAICS | n/a |
SIC | 3561 - Pumps And Pumping Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 98 |
Plant Area (Sq.Ft.) | 73,000 |
Annual Production | 20,000 Pieces |
Production Hrs. Annual | 6,732 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $172,533 | 4,730,950 | kWh | $0.04 |
Electricity Demand | $56,524 | 12,182 | kW-months/year | $4.64 |
Natural Gas | $8,063 | 1,488 | MMBtu | $5.42 |
TOTAL ENERGY COSTS | $322,543 | |||
RECOMMENDED SAVINGS* | $31,647 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,959 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (haz) | Personnel Changes | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.2121 CONVERT TO ELECTROSTATIC POWDER COATING |
Savings: $10,682 Cost: $26,600 |
$(-500) | (-13,775) | - | - | - | - | $2,000 | 4,397 | $5,606 | - | - | - | $3,576 | - |
$(-500) (-13,775) kWh |
- - kW-months/year |
- - gal |
$2,000 4,397 lb |
$5,606 - $ |
- - $ |
$3,576 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,333 Cost: $21,300 |
$7,607 | 211,313 | $1,726 | 372 | - | - | - | - | - | - | - | - | - | - |
$7,607 211,313 kWh |
$1,726 372 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $4,500 Cost: - |
$4,500 | 124,267 | - | - | - | - | - | - | - | - | - | - | - | - |
$4,500 124,267 kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $4,126 Cost: $8,500 |
- | - | - | - | - | - | - | - | - | - | $4,126 | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
$4,126 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,359 Cost: $2,300 |
$802 | 22,274 | $557 | 120 | - | - | - | - | - | - | - | - | - | - |
$802 22,274 kWh |
$557 120 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $1,311 Cost: $2,530 |
$(-100) | (-2,638) | - | - | $862 | 392,000 | - | - | - | - | - | - | $549 | - |
$(-100) (-2,638) kWh |
- - kW-months/year |
$862 392,000 gal |
- - lb |
- - $ |
- - $ |
$549 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $336 Cost: - |
$169 | 4,689 | $167 | 36 | - | - | - | - | - | - | - | - | - | - |
$169 4,689 kWh |
$167 36 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,647 Cost: $61,230 |
$12,478 | 346,130 | $2,450 | 528 | $862 | 392,000 | $2,000 | 4,397 | $5,606 | - | $4,126 | - | $4,125 | - | $12,478 346,130 kWh |
$2,450 528 kW-months/year |
$862 392,000 gal |
$2,000 4,397 lb |
$5,606 - $ |
$4,126 - $ |
$4,125 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,959 Cost: $29,800 |
$12,107 | 335,580 | $1,726 | 372 | - | - | - | - | - | - | $4,126 | - | - | - | $12,107 335,580 kWh |
$1,726 372 kW-months/year |
- - gal |
- - lb |
- - $ |
$4,126 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (haz) | Personnel Changes | Administrative Changes | Primary Raw Material |