Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1999
Principal Product Men's and Boys' Denim Jeans and Shorts
NAICS n/a
SIC 2325 - Men's and Boys' Separate Trousers and Slacks
Sales $10,000,000-$50,000,000
# of Employees 201
Plant Area (Sq.Ft.) 84,000
Annual Production 1,250,000 Pieces
Production Hrs. Annual 2,000
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $31,049 1,133,646 kWh $0.03
Electricity Demand $16,895 4,012 kW-months/year $4.21
Electricity Fees $6,304 - $ -
Natural Gas $9,047 1,705 MMBtu $5.31
TOTAL ENERGY COSTS $63,295
RECOMMENDED SAVINGS* $113,947 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $78,900
#|Description Savings
Cost
Status Electricity Usage Solid Waste (non-haz) Personnel Changes Administrative Changes Electricity Usage Solid Waste (non-haz) Personnel Changes Administrative Changes
$ kWh $ lb $ $ $ $
01: 3.5311 RECOVER AND REUSE WASTE MATERIAL Savings:
$11,400
Cost:
$2,800
- - $11,400 45,000 - - - - -
-
kWh
$11,400
45,000
lb
-
-
$
-
-
$
02: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$2,574
Cost:
$7,230
$2,320 85,873 $254 176 - - - - $2,320
85,873
kWh
$254
176
lb
-
-
$
-
-
$
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$473
Cost:
$825
$473 24,619 - - - - - - $473
24,619
kWh
-
-
lb
-
-
$
-
-
$
04: 4.421 MODIFY CURRENT INCENTIVE PROGRAM Savings:
$67,500
Cost:
$16,375
- - - - - - $67,500 - -
-
kWh
-
-
lb
-
-
$
$67,500
-
$
05: 4.112 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL Savings:
$32,000
Cost:
$78,250
- - - - $32,000 - - - -
-
kWh
-
-
lb
$32,000
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$113,947
Cost:
$105,480
$2,793 110,492 $11,654 45,176 $32,000 - $67,500 - $2,793
110,492
kWh
$11,654
45,176
lb
$32,000
-
$
$67,500
-
$
TOTAL IMPLEMENTED Savings:
$78,900
Cost:
$19,175
- - $11,400 45,000 - - $67,500 - -
-
kWh
$11,400
45,000
lb
-
-
$
$67,500
-
$
Savings
Cost
$ kWh $ lb $ $ $ $
Electricity Usage Solid Waste (non-haz) Personnel Changes Administrative Changes Electricity Usage Solid Waste (non-haz) Personnel Changes Administrative Changes