Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 2000 |
Principal Product | lawn mowers |
NAICS | n/a |
SIC | 3524 - Lawn And Garden Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 360 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 440,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $138,135 | 4,081,477 | kWh | $0.03 |
Electricity Demand | $80,353 | 10,000 | kW-months/year | $8.04 |
TOTAL ENERGY COSTS | $478,618 | |||
RECOMMENDED SAVINGS* | $205,709 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $106,272 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.421 MODIFY CURRENT INCENTIVE PROGRAM |
Savings: $77,500 Cost: $35,600 |
- | - | - | - | - | - | $77,500 | - |
- - kWh |
- - kW-months/year |
- - lb |
$77,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $69,815 Cost: $1,200 |
- | - | - | - | $69,815 | 1,135,200 | - | - |
- - kWh |
- - kW-months/year |
$69,815 1,135,200 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2691 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS |
Savings: $22,100 Cost: $8,120 |
$22,100 | 404,748 | - | - | - | - | - | - |
$22,100 404,748 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $12,000 Cost: $35,070 |
$12,000 | 319,168 | - | - | - | - | - | - |
$12,000 319,168 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $11,176 Cost: $379 |
$7,287 | 227,726 | $3,889 | 3,795 | - | - | - | - |
$7,287 227,726 kWh |
$3,889 3,795 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $8,508 Cost: $18,900 |
- | - | $8,508 | 83 | - | - | - | - |
- - kWh |
$8,508 83 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,503 Cost: $900 |
$816 | 25,498 | $687 | 7 | - | - | - | - |
$816 25,498 kWh |
$687 7 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $2,357 Cost: $490 |
$1,435 | 44,842 | $922 | 9 | - | - | - | - |
$1,435 44,842 kWh |
$922 9 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $750 Cost: $570 |
- | - | - | - | $750 | 10,000 | - | - |
- - kWh |
- - kW-months/year |
$750 10,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $205,709 Cost: $101,229 |
$43,638 | 1,021,982 | $14,006 | 3,894 | $70,565 | 1,145,200 | $77,500 | - | $43,638 1,021,982 kWh |
$14,006 3,894 kW-months/year |
$70,565 1,145,200 lb |
$77,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $106,272 Cost: $44,880 |
$35,535 | 768,758 | $922 | 9 | $69,815 | 1,135,200 | - | - | $35,535 768,758 kWh |
$922 9 kW-months/year |
$69,815 1,135,200 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||