Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Prairie View, A&M |
---|---|
Assessment Year | 2000 |
Principal Product | Photograph albums |
NAICS | n/a |
SIC | 3652 - Prerecorded Records And Tapes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 980,800 Pieces |
Production Hrs. Annual | 2,584 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $37,832 | 676,436 | kWh | $0.06 |
Electricity Demand | $7,912 | 2,234 | kW-months/year | $3.54 |
Natural Gas | $1,029 | 180 | MMBtu | $5.72 |
TOTAL ENERGY COSTS | $46,773 | |||
RECOMMENDED SAVINGS* | $22,149 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $270 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Primary Raw Material | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $12,967 Cost: - |
- | - | - | - | $12,967 | - | - | - |
- - kWh |
- - kW-months/year |
$12,967 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.114 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS |
Savings: $3,047 Cost: $96 |
- | - | - | - | - | - | $3,047 | - |
- - kWh |
- - kW-months/year |
- - $ |
$3,047 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $5,048 Cost: $3,875 |
$3,867 | 103,458 | $1,181 | 180 | - | - | - | - |
$3,867 103,458 kWh |
$1,181 180 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $460 Cost: $509 |
$259 | 7,034 | $201 | 31 | - | - | - | - |
$259 7,034 kWh |
$201 31 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $357 Cost: $384 |
$357 | 5,862 | - | - | - | - | - | - |
$357 5,862 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $270 Cost: $1,948 |
$149 | 4,103 | $121 | 19 | - | - | - | - |
$149 4,103 kWh |
$121 19 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $22,149 Cost: $6,812 |
$4,632 | 120,457 | $1,503 | 230 | $12,967 | - | $3,047 | - | $4,632 120,457 kWh |
$1,503 230 kW-months/year |
$12,967 - $ |
$3,047 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $270 Cost: $1,948 |
$149 | 4,103 | $121 | 19 | - | - | - | - | $149 4,103 kWh |
$121 19 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Primary Raw Material | Primary Product |