Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Texas Rio Grande Valley
Assessment Year 2019
Principal Product Water
NAICS 221310 - Water Supply and Irrigation Systems
SIC 4941 - Water Supply
Sales $10,000,000-$50,000,000
# of Employees 10
Plant Area (Sq.Ft.) 1,546,380
Annual Production 1,830,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $112,735 1,513,920 kWh $0.07
Electricity Demand $14,263 3,566 kW-months/year $4.00
Electricity Fees $1,020 - $ -
TOTAL ENERGY COSTS $128,018
RECOMMENDED SAVINGS* $580,729 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,851
#|Description Savings
Cost
Status Electricity Usage Water Usage Primary Raw Material Ancillary Material Cost Electricity Usage Water Usage Primary Raw Material Ancillary Material Cost
$ kWh $ Tgal $ $ $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,354
Cost:
$4,519
$2,354 28,054 - - - - - - $2,354
28,054
kWh
-
-
Tgal
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,876
Cost:
$1,778
$1,876 22,356 - - - - - - $1,876
22,356
kWh
-
-
Tgal
-
-
$
-
-
$
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,445
Cost:
-
$1,445 17,222 - - - - - - $1,445
17,222
kWh
-
-
Tgal
-
-
$
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$959
Cost:
$225
$423 5,046 - - $273 - $263 - $423
5,046
kWh
-
-
Tgal
$273
-
$
$263
-
$
05: 3.7311 MAINTAIN MACHINES TO REDUCE LEAKS Savings:
$1,751
Cost:
$1,351
- - $1,751 17 - - - - -
-
kWh
$1,751
17
Tgal
-
-
$
-
-
$
06: 3.8121 COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES Savings:
$466,053
Cost:
$1,043,438
- - $466,053 24,353 - - - - -
-
kWh
$466,053
24,353
Tgal
-
-
$
-
-
$
07: 2.7423 REDUCE HEAT GAIN BY WINDOW TINTING Savings:
$1,426
Cost:
$1,320
$1,426 16,994 - - - - - - $1,426
16,994
kWh
-
-
Tgal
-
-
$
-
-
$
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$104,866
Cost:
$89,113
$104,866 1,249,894 - - - - - - $104,866
1,249,894
kWh
-
-
Tgal
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$580,729
Cost:
$1,141,744
$112,389 1,339,565 $467,804 24,370 $273 - $263 - $112,389
1,339,565
kWh
$467,804
24,370
Tgal
$273
-
$
$263
-
$
TOTAL IMPLEMENTED Savings:
$8,851
Cost:
$8,968
$7,100 84,625 $1,751 17 - - - - $7,100
84,625
kWh
$1,751
17
Tgal
-
-
$
-
-
$
Savings
Cost
$ kWh $ Tgal $ $ $ $
Electricity Usage Water Usage Primary Raw Material Ancillary Material Cost Electricity Usage Water Usage Primary Raw Material Ancillary Material Cost