Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Texas Rio Grande Valley |
---|---|
Assessment Year | 2022 |
Principal Product | Water |
NAICS | 221310 - Water Supply and Irrigation Systems |
SIC | 4941 - Water Supply |
Sales | $1,000,000-$5,000,000 |
# of Employees | 12 |
Plant Area (Sq.Ft.) | 164,550 |
Annual Production | 2,737,500 Thousand Gallons |
Production Hrs. Annual | 8,544 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $65,065 | 833,940 | kWh | $0.08 |
Electricity Demand | $9,910 | 2,478 | kW-months/year | $4.00 |
Electricity Fees | $1,020 | - | $ | - |
TOTAL ENERGY COSTS | $75,996 | |||
RECOMMENDED SAVINGS* | $256,578 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $68,689 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Raw Material | Electricity Usage | Electricity Demand | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $512 Cost: $375 |
$478 | 5,980 | $34 | 8 | - | - |
$478 5,980 kWh |
$34 8 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.8121 COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES |
Savings: $187,890 Cost: $1,576,666 |
- | - | - | - | $187,890 | - |
- - kWh |
- - kW-months/year |
$187,890 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $68,177 Cost: $780,672 |
$59,936 | 749,199 | $8,241 | 2,060 | - | - |
$59,936 749,199 kWh |
$8,241 2,060 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $256,578 Cost: $2,357,713 |
$60,414 | 755,179 | $8,275 | 2,068 | $187,890 | - | $60,414 755,179 kWh |
$8,275 2,068 kW-months/year |
$187,890 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $68,689 Cost: $781,047 |
$60,414 | 755,179 | $8,275 | 2,068 | - | - | $60,414 755,179 kWh |
$8,275 2,068 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Raw Material | Electricity Usage | Electricity Demand | Primary Raw Material |