Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Tennessee Technological University
Assessment Year 2008
Principal Product Non-woven Fabric Treatment
NAICS 313320 - Fabric Coating Mills
SIC 2295 - Coated Fabrics, Not Rubberized
Sales $10,000,000-$50,000,000
# of Employees 83
Plant Area (Sq.Ft.) 105,000
Annual Production 53,750,000 Pounds
Production Hrs. Annual 7,800
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $253,294 5,950,000 kWh $0.04
Electricity Demand $133,273 10,599 kW-months/year $12.57
Electricity Fees $12,940 - $ -
Natural Gas $1,254,172 148,112 MMBtu $8.47
Fuel Oil #2 $26,006 2,683 MMBtu $9.69
TOTAL ENERGY COSTS $1,679,685
RECOMMENDED SAVINGS* $368,046 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $53,446
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS Savings:
$314,600
Cost:
$100,000
- - - - $314,600 36,761 - - -
-
kWh
-
-
kW-months/year
$314,600
36,761
MMBtu
-
-
$
02: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) Savings:
$33,000
Cost:
$1,000
- - - - - - $33,000 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$33,000
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$18,809
Cost:
$22,423
$13,448 314,496 $5,361 432 - - - - $13,448
314,496
kWh
$5,361
432
kW-months/year
-
-
MMBtu
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,637
Cost:
$5,950
$743 17,411 $894 72 - - - - $743
17,411
kWh
$894
72
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$368,046
Cost:
$129,373
$14,191 331,907 $6,255 504 $314,600 36,761 $33,000 - $14,191
331,907
kWh
$6,255
504
kW-months/year
$314,600
36,761
MMBtu
$33,000
-
$
TOTAL IMPLEMENTED Savings:
$53,446
Cost:
$29,373
$14,191 331,907 $6,255 504 - - $33,000 - $14,191
331,907
kWh
$6,255
504
kW-months/year
-
-
MMBtu
$33,000
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes