Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | Tennessee Technological University |
---|---|
Assessment Year | 2008 |
Principal Product | Non-woven Fabric Treatment |
NAICS | 313320 - Fabric Coating Mills |
SIC | 2295 - Coated Fabrics, Not Rubberized |
Sales | $10,000,000-$50,000,000 |
# of Employees | 83 |
Plant Area (Sq.Ft.) | 105,000 |
Annual Production | 53,750,000 Pounds |
Production Hrs. Annual | 7,800 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $253,294 | 5,950,000 | kWh | $0.04 |
Electricity Demand | $133,273 | 10,599 | kW-months/year | $12.57 |
Electricity Fees | $12,940 | - | $ | - |
Natural Gas | $1,254,172 | 148,112 | MMBtu | $8.47 |
Fuel Oil #2 | $26,006 | 2,683 | MMBtu | $9.69 |
TOTAL ENERGY COSTS | $1,679,685 | |||
RECOMMENDED SAVINGS* | $368,046 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $53,446 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS |
Savings: $314,600 Cost: $100,000 |
- | - | - | - | $314,600 | 36,761 | - | - |
- - kWh |
- - kW-months/year |
$314,600 36,761 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $33,000 Cost: $1,000 |
- | - | - | - | - | - | $33,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$33,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $18,809 Cost: $22,423 |
$13,448 | 314,496 | $5,361 | 432 | - | - | - | - |
$13,448 314,496 kWh |
$5,361 432 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,637 Cost: $5,950 |
$743 | 17,411 | $894 | 72 | - | - | - | - |
$743 17,411 kWh |
$894 72 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $368,046 Cost: $129,373 |
$14,191 | 331,907 | $6,255 | 504 | $314,600 | 36,761 | $33,000 | - | $14,191 331,907 kWh |
$6,255 504 kW-months/year |
$314,600 36,761 MMBtu |
$33,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $53,446 Cost: $29,373 |
$14,191 | 331,907 | $6,255 | 504 | - | - | $33,000 | - | $14,191 331,907 kWh |
$6,255 504 kW-months/year |
- - MMBtu |
$33,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |