Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Tennessee Technological University |
---|---|
Assessment Year | 2009 |
Principal Product | Limestone |
NAICS | 212312 - Crushed and Broken Limestone Mining and Quarrying |
SIC | 1422 - Crushed And Broken Limestone |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 1,300,000 Tons |
Production Hrs. Annual | 6,000 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $407,426 | 8,552,124 | kWh | $0.05 |
Electricity Demand | $987,189 | 58,896 | kW-months/year | $16.76 |
Electricity Fees | $48,724 | - | $ | - |
LPG | $144,830 | 9,720 | MMBtu | $14.90 |
TOTAL ENERGY COSTS | $1,588,169 | |||
RECOMMENDED SAVINGS* | $59,830 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $55,400 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $38,600 Cost: $28,400 |
- | - | - | - | $38,600 | 2,591 | - | - |
- - kWh |
- - kW-months/year |
$38,600 2,591 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $16,800 Cost: $2,900 |
$9,000 | 318,000 | $7,800 | 636 | - | - | - | - |
$9,000 318,000 kWh |
$7,800 636 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,430 Cost: $20,000 |
$1,850 | 64,800 | $1,600 | 130 | - | - | $980 | - |
$1,850 64,800 kWh |
$1,600 130 kW-months/year |
- - MMBtu |
$980 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $59,830 Cost: $51,300 |
$10,850 | 382,800 | $9,400 | 766 | $38,600 | 2,591 | $980 | - | $10,850 382,800 kWh |
$9,400 766 kW-months/year |
$38,600 2,591 MMBtu |
$980 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $55,400 Cost: $31,300 |
$9,000 | 318,000 | $7,800 | 636 | $38,600 | 2,591 | - | - | $9,000 318,000 kWh |
$7,800 636 kW-months/year |
$38,600 2,591 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes |