Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Tennessee Technological University |
---|---|
Assessment Year | 2010 |
Principal Product | steel stamping |
NAICS | 336370 - Motor Vehicle Metal Stamping |
SIC | 3465 - Automotive Stampings |
Sales | $100,000,000-$500,000,000 |
# of Employees | 322 |
Plant Area (Sq.Ft.) | 680,000 |
Annual Production | 29,641,500 Pieces |
Production Hrs. Annual | 4,750 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $586,727 | 14,510,000 | kWh | $0.04 |
Electricity Demand | $504,029 | 37,453 | kW-months/year | $13.46 |
Electricity Fees | $65,618 | - | $ | - |
Natural Gas | $77,136 | 5,901 | MMBtu | $13.07 |
TOTAL ENERGY COSTS | $1,313,040 | |||
RECOMMENDED SAVINGS* | $211,800 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $56,000 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $56,000 Cost: $1,000 |
$24,500 | 766,400 | $31,500 | 2,417 | - | - | - | - |
$24,500 766,400 kWh |
$31,500 2,417 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $97,000 Cost: $421,000 |
$35,400 | 1,105,800 | $36,400 | 2,794 | - | - | $25,200 | - |
$35,400 1,105,800 kWh |
$36,400 2,794 kW-months/year |
- - $ |
$25,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $35,900 Cost: $91,150 |
$16,000 | 498,750 | $16,400 | 1,260 | $3,500 | - | - | - |
$16,000 498,750 kWh |
$16,400 1,260 kW-months/year |
$3,500 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $18,500 Cost: $4,500 |
$18,500 | 579,300 | - | - | - | - | - | - |
$18,500 579,300 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,400 Cost: $4,500 |
$4,400 | 134,900 | - | - | - | - | - | - |
$4,400 134,900 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $211,800 Cost: $522,150 |
$98,800 | 3,085,150 | $84,300 | 6,471 | $3,500 | - | $25,200 | - | $98,800 3,085,150 kWh |
$84,300 6,471 kW-months/year |
$3,500 - $ |
$25,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $56,000 Cost: $1,000 |
$24,500 | 766,400 | $31,500 | 2,417 | - | - | - | - | $24,500 766,400 kWh |
$31,500 2,417 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||