IAC logo
IAC Assessment: TT0093
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TT0093
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Tennessee Technological University
Assessment Year 2012
Principal Product Plastics Packaging
NAICS 326112 - Plastics Packaging Film and Sheet (including Laminated) Manufacturing
SIC 2671 - Paper Coated & Laminated, Packaging
Sales <$500,000
# of Employees 42
Plant Area (Sq.Ft.) 1,001
Annual Production 0 Units
Production Hrs. Annual 4,000
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $81,750 1,261,440 kWh $0.06
Electricity Demand $55,511 5,397 kW-months/year $10.29
Electricity Fees $5,622 - $ -
LPG $13,538 838 MMBtu $16.16
TOTAL ENERGY COSTS $158,361
RECOMMENDED SAVINGS* $63,714 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,989
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$21,234
Cost:
$10,343
$21,234 298,845 $21,234
298,845
kWh
02: 2.9121 INSTALL WIND POWERED ELECTRIC GENERATOR Savings:
$29,491
Cost:
$250,000
$29,491 249,924 $29,491
249,924
kWh
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$3,625
Cost:
$52,000
$3,625 56,640 $3,625
56,640
kWh
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$8,350
Cost:
$800
$8,350 92,746 $8,350
92,746
kWh
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,014
Cost:
$7,685
$1,014 14,484 $1,014
14,484
kWh
TOTAL RECOMMENDED Savings:
$63,714
Cost:
$320,828
$63,714 712,639 $63,714
712,639
kWh
TOTAL IMPLEMENTED Savings:
$12,989
Cost:
$60,485
$12,989 163,870 $12,989
163,870
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage