IAC Center | Tennessee Technological University |
---|---|
Assessment Year | 2021 |
Principal Product | Transportation Trailers |
NAICS | 336999 - All Other Transportation Equipment Manufacturing |
SIC | 3799 - Transportation Equipment, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 310,000 |
Annual Production | 2,600 Units |
Production Hrs. Annual | 5,512 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $163,500 | 2,654,400 | kWh | $0.06 |
Electricity Demand | $161,410 | 10,271 | kW-months/year | $15.72 |
Natural Gas | $187,531 | 19,601 | MMBtu | $9.57 |
TOTAL ENERGY COSTS | $515,930 | |||
RECOMMENDED SAVINGS* | $111,862 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $32,663 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $45,807 Cost: $72,000 |
- | - | - | - | $45,807 | 4,787 | - | - |
- - kWh |
- - kW-months/year |
$45,807 4,787 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $32,663 Cost: $88,815 |
$20,948 | 342,295 | $11,715 | 745 | - | - | - | - |
$20,948 342,295 kWh |
$11,715 745 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $19,566 Cost: $6,725 |
$19,566 | 319,710 | - | - | - | - | - | - |
$19,566 319,710 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $9,686 Cost: $17,700 |
$(-1,776) | (-29,014) | - | - | - | - | $11,462 | - |
$(-1,776) (-29,014) kWh |
- - kW-months/year |
- - MMBtu |
$11,462 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $4,140 Cost: $5,000 |
- | - | - | - | $4,140 | 433 | - | - |
- - kWh |
- - kW-months/year |
$4,140 433 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $111,862 Cost: $190,240 |
$38,738 | 632,991 | $11,715 | 745 | $49,947 | 5,220 | $11,462 | - | $38,738 632,991 kWh |
$11,715 745 kW-months/year |
$49,947 5,220 MMBtu |
$11,462 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $32,663 Cost: $88,815 |
$20,948 | 342,295 | $11,715 | 745 | - | - | - | - | $20,948 342,295 kWh |
$11,715 745 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |