Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Tennessee Technological University |
---|---|
Assessment Year | 2022 |
Principal Product | Porcelain Tile Manufacturing and Processing |
NAICS | 327120 - Clay Building Material and Refractories Manufacturing |
SIC | 3253 - Ceramic Wall And Floor Tile |
Sales | $50,000,000-$100,000,000 |
# of Employees | 445 |
Plant Area (Sq.Ft.) | 750,000 |
Annual Production | 30,000,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,238,125 | 29,471,850 | kWh | $0.04 |
Electricity Demand | $1,073,036 | 136,662 | kW-months/year | $7.85 |
Natural Gas | $1,781,887 | 508,332 | MMBtu | $3.51 |
TOTAL ENERGY COSTS | $4,096,766 | |||
RECOMMENDED SAVINGS* | $144,544 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $45,717 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE |
Savings: $67,587 Cost: $45,000 |
- | - | - | - | - | - | $67,587 | 19,283 |
- - kWh |
- - kW-months/year |
- - $ |
$67,587 19,283 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $17,048 Cost: $14,849 |
- | - | - | - | $17,048 | - | - | - |
- - kWh |
- - kW-months/year |
$17,048 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $16,038 Cost: $18,000 |
$16,038 | 381,848 | - | - | - | - | - | - |
$16,038 381,848 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,631 Cost: $17,010 |
$9,804 | 233,436 | $2,827 | 360 | - | - | - | - |
$9,804 233,436 kWh |
$2,827 360 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $9,510 Cost: $12,000 |
$7,571 | 180,280 | $1,939 | 247 | - | - | - | - |
$7,571 180,280 kWh |
$1,939 247 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $9,445 Cost: $5,000 |
$7,485 | 178,214 | $1,960 | 250 | - | - | - | - |
$7,485 178,214 kWh |
$1,960 250 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,489 Cost: $1,920 |
$6,353 | 151,283 | $136 | 17 | - | - | - | - |
$6,353 151,283 kWh |
$136 17 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $5,797 Cost: $5,000 |
- | - | - | - | - | - | $5,797 | 1,654 |
- - kWh |
- - kW-months/year |
- - $ |
$5,797 1,654 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $144,544 Cost: $118,779 |
$47,251 | 1,125,061 | $6,861 | 874 | $17,048 | - | $73,384 | 20,937 | $47,251 1,125,061 kWh |
$6,861 874 kW-months/year |
$17,048 - $ |
$73,384 20,937 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $45,717 Cost: $49,859 |
$25,842 | 615,284 | $2,827 | 360 | $17,048 | - | - | - | $25,842 615,284 kWh |
$2,827 360 kW-months/year |
$17,048 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |