Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Tennessee Technological University |
---|---|
Assessment Year | 2024 |
Principal Product | Metal Fabrication |
NAICS | 332119 - Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
SIC | 3499 - Fabricated Metal Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 53 |
Plant Area (Sq.Ft.) | 125,000 |
Annual Production | 17,483,221 Units |
Production Hrs. Annual | 4,550 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $63,705 | 663,500 | kWh | $0.10 |
Electricity Demand | $21,242 | 2,182 | kW-months/year | $9.74 |
Natural Gas | $14,256 | 1,349 | MMBtu | $10.57 |
TOTAL ENERGY COSTS | $101,427 | |||
RECOMMENDED SAVINGS* | $20,968 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,784 Cost: $3,840 |
$3,774 | 39,312 | $1,010 | 104 | - | - | - | - | - | - |
$3,774 39,312 kWh |
$1,010 104 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $4,348 Cost: - |
- | - | - | - | - | - | - | - | $4,348 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
$4,348 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $3,460 Cost: $1,590 |
- | - | - | - | $2,347 | 141 | $1,113 | 141 | - | - |
- - kWh |
- - kW-months/year |
$2,347 141 Tgal |
$1,113 141 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $3,347 Cost: $2,600 |
$3,347 | 34,866 | - | - | - | - | - | - | - | - |
$3,347 34,866 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,321 Cost: $1,560 |
$1,321 | 13,764 | - | - | - | - | - | - | - | - |
$1,321 13,764 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $917 Cost: $113 |
$917 | 9,555 | - | - | - | - | - | - | - | - |
$917 9,555 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $828 Cost: $840 |
$828 | 8,620 | - | - | - | - | - | - | - | - |
$828 8,620 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $819 Cost: $785 |
$819 | 8,529 | - | - | - | - | - | - | - | - |
$819 8,529 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $650 Cost: $100 |
$650 | 6,773 | - | - | - | - | - | - | - | - |
$650 6,773 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $494 Cost: $1,400 |
$494 | 5,148 | - | - | - | - | - | - | - | - |
$494 5,148 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,968 Cost: $12,828 |
$12,150 | 126,567 | $1,010 | 104 | $2,347 | 141 | $1,113 | 141 | $4,348 | - | $12,150 126,567 kWh |
$1,010 104 kW-months/year |
$2,347 141 Tgal |
$1,113 141 Tgal |
$4,348 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Administrative Changes |