Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2014 |
Principal Product | Metal/Plastic Automotive Parts |
NAICS | 336370 - Motor Vehicle Metal Stamping |
SIC | 3363 - Aluminum Die-castings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 296 |
Plant Area (Sq.Ft.) | 155,000 |
Annual Production | 336,000,000 Units |
Production Hrs. Annual | 6,336 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $708,345 | 12,758,817 | kWh | $0.06 |
Electricity Demand | $156,155 | 32,071 | kW-months/year | $4.87 |
Electricity Fees | $99,946 | - | $ | - |
Natural Gas | $4,467 | 342 | MMBtu | $13.06 |
TOTAL ENERGY COSTS | $968,913 | |||
RECOMMENDED SAVINGS* | $114,182 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,621 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $57,076 Cost: $122,855 |
$46,050 | 829,433 | $7,651 | 1,571 | $3,375 | - | - | - |
$46,050 829,433 kWh |
$7,651 1,571 kW-months/year |
$3,375 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7122 DISCONNECT BALLASTS |
Savings: $14,055 Cost: $1,200 |
$11,229 | 202,246 | $1,866 | 383 | $960 | - | - | - |
$11,229 202,246 kWh |
$1,866 383 kW-months/year |
$960 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $8,580 Cost: $6,440 |
$7,994 | 143,989 | - | - | $586 | - | - | - |
$7,994 143,989 kWh |
- - kW-months/year |
$586 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,605 Cost: $6,195 |
$6,170 | 111,134 | $916 | 188 | $519 | - | - | - |
$6,170 111,134 kWh |
$916 188 kW-months/year |
$519 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $3,304 Cost: $583 |
$3,078 | 55,447 | - | - | $226 | - | - | - |
$3,078 55,447 kWh |
- - kW-months/year |
$226 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $4,317 Cost: $625 |
$2,489 | 44,824 | - | - | $182 | - | $1,646 | 126 |
$2,489 44,824 kWh |
- - kW-months/year |
$182 - $ |
$1,646 126 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $19,245 Cost: $19,520 |
- | - | - | - | $19,245 | - | - | - |
- - kWh |
- - kW-months/year |
$19,245 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $114,182 Cost: $157,418 |
$77,010 | 1,387,073 | $10,433 | 2,142 | $25,093 | - | $1,646 | 126 | $77,010 1,387,073 kWh |
$10,433 2,142 kW-months/year |
$25,093 - $ |
$1,646 126 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,621 Cost: $1,208 |
$5,567 | 100,271 | - | - | $408 | - | $1,646 | 126 | $5,567 100,271 kWh |
- - kW-months/year |
$408 - $ |
$1,646 126 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |