Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2016 |
Principal Product | Plastic Fuel Tanks |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $10,000,000-$50,000,000 |
# of Employees | 71 |
Plant Area (Sq.Ft.) | 216,000 |
Annual Production | 339,843 Pieces |
Production Hrs. Annual | 6,300 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $274,013 | 6,697,620 | kWh | $0.04 |
Electricity Demand | $43,426 | 9,450 | kW-months/year | $4.60 |
Electricity Fees | $116,493 | - | $ | - |
TOTAL ENERGY COSTS | $433,932 | |||
RECOMMENDED SAVINGS* | $136,079 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $40,033 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $61,044 Cost: $120 |
$49,012 | 1,198,049 | - | - | $12,032 | - |
$49,012 1,198,049 kWh |
- - kW-months/year |
$12,032 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $19,730 Cost: $50,000 |
$14,694 | 359,188 | $1,147 | 250 | $3,889 | - |
$14,694 359,188 kWh |
$1,147 250 kW-months/year |
$3,889 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $24,633 Cost: $100 |
$15,119 | 369,578 | $4,757 | 926 | $4,757 | - |
$15,119 369,578 kWh |
$4,757 926 kW-months/year |
$4,757 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,924 Cost: $2,995 |
$2,436 | 59,550 | $397 | 86 | $91 | - |
$2,436 59,550 kWh |
$397 86 kW-months/year |
$91 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $9,574 Cost: - |
$7,687 | 187,901 | - | - | $1,887 | - |
$7,687 187,901 kWh |
- - kW-months/year |
$1,887 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $5,826 Cost: $2,520 |
$3,051 | 74,576 | $1,627 | 354 | $1,148 | - |
$3,051 74,576 kWh |
$1,627 354 kW-months/year |
$1,148 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $7,261 Cost: $5,208 |
$4,801 | 117,346 | $1,029 | 224 | $1,431 | - |
$4,801 117,346 kWh |
$1,029 224 kW-months/year |
$1,431 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,480 Cost: $15,842 |
$2,963 | 72,433 | $634 | 138 | $883 | - |
$2,963 72,433 kWh |
$634 138 kW-months/year |
$883 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $607 Cost: $582 |
$487 | 11,906 | - | - | $120 | - |
$487 11,906 kWh |
- - kW-months/year |
$120 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $136,079 Cost: $77,367 |
$100,250 | 2,450,527 | $9,591 | 1,978 | $26,238 | - | $100,250 2,450,527 kWh |
$9,591 1,978 kW-months/year |
$26,238 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $40,033 Cost: $2,620 |
$25,857 | 632,055 | $6,384 | 1,280 | $7,792 | - | $25,857 632,055 kWh |
$6,384 1,280 kW-months/year |
$7,792 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |