Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2016 |
Principal Product | Walk-in coolers and freezers |
NAICS | 334515 - Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 163 |
Plant Area (Sq.Ft.) | 130,651 |
Annual Production | 50,000 Units |
Production Hrs. Annual | 3,000 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $113,397 | 1,402,800 | kWh | $0.08 |
Electricity Demand | $12,083 | 4,932 | kW-months/year | $2.45 |
Electricity Fees | $16,233 | - | $ | - |
Natural Gas | $23,734 | 3,698 | MMBtu | $6.42 |
TOTAL ENERGY COSTS | $165,447 | |||
RECOMMENDED SAVINGS* | $13,836 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,886 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,559 Cost: $20,740 |
$6,252 | 77,334 | $758 | 309 | $549 | - |
$6,252 77,334 kWh |
$758 309 kW-months/year |
$549 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,391 Cost: $250 |
$1,882 | 23,279 | $335 | 137 | $174 | - |
$1,882 23,279 kWh |
$335 137 kW-months/year |
$174 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,551 Cost: $1,770 |
$1,244 | 15,390 | $194 | 79 | $113 | - |
$1,244 15,390 kWh |
$194 79 kW-months/year |
$113 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,758 Cost: - |
$1,630 | 20,160 | - | - | $128 | - |
$1,630 20,160 kWh |
- - kW-months/year |
$128 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $577 Cost: $540 |
$441 | 5,461 | $94 | 39 | $42 | - |
$441 5,461 kWh |
$94 39 kW-months/year |
$42 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $13,836 Cost: $23,300 |
$11,449 | 141,624 | $1,381 | 564 | $1,006 | - | $11,449 141,624 kWh |
$1,381 564 kW-months/year |
$1,006 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,886 Cost: $2,310 |
$3,315 | 41,011 | $288 | 118 | $283 | - | $3,315 41,011 kWh |
$288 118 kW-months/year |
$283 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |