Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2017 |
Principal Product | Residential door assemblies |
NAICS | 321911 - Wood Window and Door Manufacturing |
SIC | 2431 - Millwork |
Sales | $10,000,000-$50,000,000 |
# of Employees | 230 |
Plant Area (Sq.Ft.) | 360,000 |
Annual Production | 875,000 Units |
Production Hrs. Annual | 2,475 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $167,073 | 2,631,550 | kWh | $0.06 |
Electricity Demand | $11,964 | 2,524 | kW-months/year | $4.74 |
Electricity Fees | $70,500 | - | $ | - |
Natural Gas | $3,786 | 254 | MMBtu | $14.91 |
TOTAL ENERGY COSTS | $253,323 | |||
RECOMMENDED SAVINGS* | $86,638 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $47,414 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $29,064 Cost: $1,800 |
$28,182 | 443,888 | - | - | $882 | - | - | - |
$28,182 443,888 kWh |
- - kW-months/year |
$882 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $9,077 Cost: $16,027 |
$8,802 | 138,647 | - | - | $275 | - | - | - |
$8,802 138,647 kWh |
- - kW-months/year |
$275 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,883 Cost: $34,772 |
$7,036 | 110,816 | $2,547 | 537 | $300 | - | - | - |
$7,036 110,816 kWh |
$2,547 537 kW-months/year |
$300 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $21,678 Cost: $38,382 |
$21,020 | 331,082 | - | - | $658 | - | - | - |
$21,020 331,082 kWh |
- - kW-months/year |
$658 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $9,273 Cost: $2,645 |
$6,570 | 103,487 | $2,422 | 511 | $281 | - | - | - |
$6,570 103,487 kWh |
$2,422 511 kW-months/year |
$281 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $5,859 Cost: $400 |
$3,562 | 56,096 | $2,119 | 447 | $178 | - | - | - |
$3,562 56,096 kWh |
$2,119 447 kW-months/year |
$178 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.454 MODIFY STARTUP/SHUTDOWN TIMES |
Savings: $1,804 Cost: - |
- | - | - | - | $55 | - | $1,749 | - |
- - kWh |
- - kW-months/year |
$55 - $ |
$1,749 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $86,638 Cost: $94,026 |
$75,172 | 1,184,016 | $7,088 | 1,495 | $2,629 | - | $1,749 | - | $75,172 1,184,016 kWh |
$7,088 1,495 kW-months/year |
$2,629 - $ |
$1,749 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $47,414 Cost: $20,472 |
$43,554 | 686,022 | $2,422 | 511 | $1,438 | - | - | - | $43,554 686,022 kWh |
$2,422 511 kW-months/year |
$1,438 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes |