Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2019 |
Principal Product | Glulam Beam |
NAICS | 321999 - All Other Miscellaneous Wood Product Manufacturing |
SIC | 2499 - Wood Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 40 |
Plant Area (Sq.Ft.) | 47,500 |
Annual Production | 10,000,000 Units |
Production Hrs. Annual | 3,146 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $117,705 | 1,177,836 | kWh | $0.10 |
Electricity Demand | $30,973 | 8,230 | kW-months/year | $3.76 |
Electricity Fees | $35,837 | - | $ | - |
Natural Gas | $43,588 | 3,490 | MMBtu | $12.49 |
TOTAL ENERGY COSTS | $228,103 | |||
RECOMMENDED SAVINGS* | $30,348 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,914 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,597 Cost: $23,433 |
$10,756 | 107,634 | $2,088 | 555 | $753 | - |
$10,756 107,634 kWh |
$2,088 555 kW-months/year |
$753 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,777 Cost: $7,719 |
$1,661 | 16,624 | - | - | $116 | - |
$1,661 16,624 kWh |
- - kW-months/year |
$116 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,238 Cost: $2,765 |
$3,592 | 35,949 | $369 | 98 | $277 | - |
$3,592 35,949 kWh |
$369 98 kW-months/year |
$277 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $3,434 Cost: $8,870 |
$2,649 | 26,507 | $560 | 149 | $225 | - |
$2,649 26,507 kWh |
$560 149 kW-months/year |
$225 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,053 Cost: $200 |
$2,528 | 25,294 | $325 | 86 | $200 | - |
$2,528 25,294 kWh |
$325 86 kW-months/year |
$200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $3,682 Cost: $2,568 |
- | - | $3,441 | 914 | $241 | - |
- - kWh |
$3,441 914 kW-months/year |
$241 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $567 Cost: $486 |
$435 | 4,350 | $95 | 25 | $37 | - |
$435 4,350 kWh |
$95 25 kW-months/year |
$37 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $30,348 Cost: $46,041 |
$21,621 | 216,358 | $6,878 | 1,827 | $1,849 | - | $21,621 216,358 kWh |
$6,878 1,827 kW-months/year |
$1,849 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,914 Cost: $37,171 |
$18,972 | 189,851 | $6,318 | 1,678 | $1,624 | - | $18,972 189,851 kWh |
$6,318 1,678 kW-months/year |
$1,624 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |