Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2019 |
Principal Product | Overcoats |
NAICS | 315280 - Other Cut and Sew Apparel Manufacturing |
SIC | 2385 - Waterproof Outerwear |
Sales | $5,000,000-$10,000,000 |
# of Employees | 236 |
Plant Area (Sq.Ft.) | 162,348 |
Annual Production | 239,905 Units |
Production Hrs. Annual | 2,100 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $242,948 | 2,819,558 | kWh | $0.09 |
Electricity Demand | $143,517 | 9,535 | kW-months/year | $15.05 |
Electricity Fees | $35,587 | - | $ | - |
Natural Gas | $24,253 | 1,850 | MMBtu | $13.11 |
TOTAL ENERGY COSTS | $446,305 | |||
RECOMMENDED SAVINGS* | $72,667 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $72,429 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $66,234 Cost: $104,269 |
$28,912 | 335,528 | $28,859 | 1,915 | $8,463 | - | - | - |
$28,912 335,528 kWh |
$28,859 1,915 kW-months/year |
$8,463 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $238 Cost: $145 |
$208 | 2,410 | - | - | $30 | - | - | - |
$208 2,410 kWh |
- - kW-months/year |
$30 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,219 Cost: $250 |
$1,556 | 18,056 | $1,252 | 83 | $411 | - | - | - |
$1,556 18,056 kWh |
$1,252 83 kW-months/year |
$411 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,537 Cost: $1,285 |
$1,404 | 16,296 | $809 | 54 | $324 | - | - | - |
$1,404 16,296 kWh |
$809 54 kW-months/year |
$324 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $439 Cost: $1,082 |
- | - | - | - | - | - | $439 | 34 |
- - kWh |
- - kW-months/year |
- - $ |
$439 34 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $72,667 Cost: $107,031 |
$32,080 | 372,290 | $30,920 | 2,052 | $9,228 | - | $439 | 34 | $32,080 372,290 kWh |
$30,920 2,052 kW-months/year |
$9,228 - $ |
$439 34 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $72,429 Cost: $106,886 |
$31,872 | 369,880 | $30,920 | 2,052 | $9,198 | - | $439 | 34 | $31,872 369,880 kWh |
$30,920 2,052 kW-months/year |
$9,198 - $ |
$439 34 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |