Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2019 |
Principal Product | Steel Golf Shafts |
NAICS | 339920 - Sporting and Athletic Goods Manufacturing |
SIC | 3949 - Sporting And Athletic Goods, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 308,711 |
Annual Production | 7,680,000 Units |
Production Hrs. Annual | 6,336 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $755,098 | 13,256,158 | kWh | $0.06 |
Electricity Demand | $453,453 | 38,562 | kW-months/year | $11.76 |
Electricity Fees | $101,457 | - | $ | - |
Natural Gas | $874,526 | 218,806 | MMBtu | $4.00 |
TOTAL ENERGY COSTS | $2,232,459 | |||
RECOMMENDED SAVINGS* | $277,811 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $185,497 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $21,674 Cost: $35,762 |
$14,375 | 252,363 | $5,621 | 478 | $1,678 | - | - | - | - | - | - | - |
$14,375 252,363 kWh |
$5,621 478 kW-months/year |
$1,678 - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $13,341 Cost: $8,495 |
$8,792 | 154,351 | $3,516 | 299 | $1,033 | - | - | - | - | - | - | - |
$8,792 154,351 kWh |
$3,516 299 kW-months/year |
$1,033 - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $22,118 Cost: $50 |
$14,409 | 252,960 | $5,997 | 510 | $1,712 | - | - | - | - | - | - | - |
$14,409 252,960 kWh |
$5,997 510 kW-months/year |
$1,712 - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $48,099 Cost: $7,241 |
$28,583 | 501,811 | $22,812 | 1,940 | $4,312 | - | $(-7,608) | (-1,902) | - | - | - | - |
$28,583 501,811 kWh |
$22,812 1,940 kW-months/year |
$4,312 - $ |
$(-7,608) (-1,902) MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $13,824 Cost: $6,704 |
- | - | - | - | - | - | $13,824 | 3,456 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$13,824 3,456 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $58,766 Cost: $50 |
$38,977 | 684,288 | $15,240 | 1,296 | $4,549 | - | - | - | - | - | - | - |
$38,977 684,288 kWh |
$15,240 1,296 kW-months/year |
$4,549 - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $57,024 Cost: $7,375 |
- | - | - | - | - | - | $57,024 | 14,256 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$57,024 14,256 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $33,548 Cost: $5,698 |
- | - | - | - | - | - | - | - | $33,548 | 9,345 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$33,548 9,345 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $9,417 Cost: - |
- | - | - | - | - | - | - | - | - | - | $9,417 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$9,417 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $277,811 Cost: $71,375 |
$105,136 | 1,845,773 | $53,186 | 4,523 | $13,284 | - | $63,240 | 15,810 | $33,548 | 9,345 | $9,417 | - | $105,136 1,845,773 kWh |
$53,186 4,523 kW-months/year |
$13,284 - $ |
$63,240 15,810 MMBtu |
$33,548 9,345 Tgal |
$9,417 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $185,497 Cost: $65,627 |
$66,159 | 1,161,485 | $37,946 | 3,227 | $8,735 | - | $63,240 | 15,810 | - | - | $9,417 | - | $66,159 1,161,485 kWh |
$37,946 3,227 kW-months/year |
$8,735 - $ |
$63,240 15,810 MMBtu |
- - Tgal |
$9,417 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Administrative Changes |