Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2019 |
Principal Product | Composite Bus Panels |
NAICS | 336211 - Motor Vehicle Body Manufacturing |
SIC | 3713 - Truck And Bus Bodies |
Sales | $100,000,000-$500,000,000 |
# of Employees | 64 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 7,500 Units |
Production Hrs. Annual | 2,125 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $101,149 | 916,200 | kWh | $0.11 |
Electricity Demand | $19,280 | 4,815 | kW-months/year | $4.00 |
Electricity Fees | $7,243 | - | $ | - |
Natural Gas | $47,219 | 4,650 | MMBtu | $10.15 |
TOTAL ENERGY COSTS | $174,891 | |||
RECOMMENDED SAVINGS* | $19,802 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,811 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $12,317 Cost: $50 |
$11,619 | 105,243 | - | - | $698 | - |
$11,619 105,243 kWh |
- - kW-months/year |
$698 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,328 Cost: $11,266 |
$4,173 | 37,799 | $853 | 213 | $302 | - |
$4,173 37,799 kWh |
$853 213 kW-months/year |
$302 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $663 Cost: $539 |
$625 | 5,658 | - | - | $38 | - |
$625 5,658 kWh |
- - kW-months/year |
$38 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $816 Cost: $50 |
$610 | 5,524 | $160 | 40 | $46 | - |
$610 5,524 kWh |
$160 40 kW-months/year |
$46 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $678 Cost: $970 |
$564 | 5,109 | $76 | 19 | $38 | - |
$564 5,109 kWh |
$76 19 kW-months/year |
$38 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,802 Cost: $12,875 |
$17,591 | 159,333 | $1,089 | 272 | $1,122 | - | $17,591 159,333 kWh |
$1,089 272 kW-months/year |
$1,122 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,811 Cost: $1,070 |
$12,793 | 115,876 | $236 | 59 | $782 | - | $12,793 115,876 kWh |
$236 59 kW-months/year |
$782 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |