Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Alabama
Assessment Year 2021
Principal Product Yarn
NAICS 313110 - Fiber, Yarn, and Thread Mills
SIC 2281 - Yarn Spinning Mills
Sales $10,000,000-$50,000,000
# of Employees 131
Plant Area (Sq.Ft.) 610,000
Annual Production 7,000,000 Pounds
Production Hrs. Annual 8,760
Location (State) AL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,870,617 32,852,780 kWh $0.06
Electricity Demand $252,178 51,803 kW-months/year $4.87
Electricity Fees $43,305 - $ -
TOTAL ENERGY COSTS $2,166,100
RECOMMENDED SAVINGS* $86,444 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$45,808
Cost:
$43,308
$40,185 705,744 $4,707 967 $916 - $40,185
705,744
kWh
$4,707
967
kW-months/year
$916
-
$
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$323
Cost:
$197
$317 5,464 - - $6 - $317
5,464
kWh
-
-
kW-months/year
$6
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$21,374
Cost:
$22,712
$18,747 329,240 $2,200 452 $427 - $18,747
329,240
kWh
$2,200
452
kW-months/year
$427
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$8,257
Cost:
$1,579
$8,014 140,742 $78 16 $165 - $8,014
140,742
kWh
$78
16
kW-months/year
$165
-
$
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$10,365
Cost:
$250
$9,060 159,112 $1,098 226 $207 - $9,060
159,112
kWh
$1,098
226
kW-months/year
$207
-
$
06: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$317
Cost:
$450
$311 5,460 - - $6 - $311
5,460
kWh
-
-
kW-months/year
$6
-
$
TOTAL RECOMMENDED Savings:
$86,444
Cost:
$68,496
$76,634 1,345,762 $8,083 1,661 $1,727 - $76,634
1,345,762
kWh
$8,083
1,661
kW-months/year
$1,727
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees