IAC Center | University of Alabama |
---|---|
Assessment Year | 2021 |
Principal Product | Jet Fuel Filter |
NAICS | 333999 - All Other Miscellaneous General Purpose Machinery Manufacturing |
SIC | 3599 - Industrial Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 71 |
Plant Area (Sq.Ft.) | 125,000 |
Annual Production | 360,000 Units |
Production Hrs. Annual | 2,958 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $68,261 | 1,449,280 | kWh | $0.05 |
Electricity Demand | $40,629 | 4,170 | kW-months/year | $9.74 |
Electricity Fees | $7,316 | - | $ | - |
Natural Gas | $43,411 | 5,735 | MMBtu | $7.57 |
TOTAL ENERGY COSTS | $159,617 | |||
RECOMMENDED SAVINGS* | $28,978 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,977 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,396 Cost: $17,269 |
$2,865 | 60,833 | $2,407 | 247 | $124 | - | - | - |
$2,865 60,833 kWh |
$2,407 247 kW-months/year |
$124 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $15,788 Cost: $20,165 |
- | - | - | - | - | - | $15,788 | 2,086 |
- - kWh |
- - kW-months/year |
- - $ |
$15,788 2,086 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $320 Cost: $20 |
$313 | 6,652 | - | - | $7 | - | - | - |
$313 6,652 kWh |
- - kW-months/year |
$7 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,213 Cost: $100 |
$1,238 | 26,292 | $924 | 95 | $51 | - | - | - |
$1,238 26,292 kWh |
$924 95 kW-months/year |
$51 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $5,261 Cost: $8,080 |
- | - | - | - | - | - | $5,261 | 695 |
- - kWh |
- - kW-months/year |
- - $ |
$5,261 695 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $28,978 Cost: $45,634 |
$4,416 | 93,777 | $3,331 | 342 | $182 | - | $21,049 | 2,781 | $4,416 93,777 kWh |
$3,331 342 kW-months/year |
$182 - $ |
$21,049 2,781 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,977 Cost: $25,369 |
$3,178 | 67,485 | $2,407 | 247 | $131 | - | $5,261 | 695 | $3,178 67,485 kWh |
$2,407 247 kW-months/year |
$131 - $ |
$5,261 695 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |