Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Alabama
Assessment Year 2021
Principal Product Jet Fuel Filter
NAICS 333999 - All Other Miscellaneous General Purpose Machinery Manufacturing
SIC 3599 - Industrial Machinery, Nec
Sales $10,000,000-$50,000,000
# of Employees 71
Plant Area (Sq.Ft.) 125,000
Annual Production 360,000 Units
Production Hrs. Annual 2,958
Location (State) AL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $68,261 1,449,280 kWh $0.05
Electricity Demand $40,629 4,170 kW-months/year $9.74
Electricity Fees $7,316 - $ -
Natural Gas $43,411 5,735 MMBtu $7.57
TOTAL ENERGY COSTS $159,617
RECOMMENDED SAVINGS* $28,978 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $10,977
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,396
Cost:
$17,269
$2,865 60,833 $2,407 247 $124 - - - $2,865
60,833
kWh
$2,407
247
kW-months/year
$124
-
$
-
-
MMBtu
02: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$15,788
Cost:
$20,165
- - - - - - $15,788 2,086 -
-
kWh
-
-
kW-months/year
-
-
$
$15,788
2,086
MMBtu
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$320
Cost:
$20
$313 6,652 - - $7 - - - $313
6,652
kWh
-
-
kW-months/year
$7
-
$
-
-
MMBtu
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,213
Cost:
$100
$1,238 26,292 $924 95 $51 - - - $1,238
26,292
kWh
$924
95
kW-months/year
$51
-
$
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,261
Cost:
$8,080
- - - - - - $5,261 695 -
-
kWh
-
-
kW-months/year
-
-
$
$5,261
695
MMBtu
TOTAL RECOMMENDED Savings:
$28,978
Cost:
$45,634
$4,416 93,777 $3,331 342 $182 - $21,049 2,781 $4,416
93,777
kWh
$3,331
342
kW-months/year
$182
-
$
$21,049
2,781
MMBtu
TOTAL IMPLEMENTED Savings:
$10,977
Cost:
$25,369
$3,178 67,485 $2,407 247 $131 - $5,261 695 $3,178
67,485
kWh
$2,407
247
kW-months/year
$131
-
$
$5,261
695
MMBtu