Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Alabama
Assessment Year 2024
Principal Product Hydraulic Cylinders
NAICS 333995 - Fluid Power Cylinder and Actuator Manufacturing
SIC 3593 - Fluid Power Cylinders & Actuators
Sales $10,000,000-$50,000,000
# of Employees 86
Plant Area (Sq.Ft.) 140,000
Annual Production 9,928 Units
Production Hrs. Annual 2,000
Location (State) AL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $269,966 3,788,039 kWh $0.07
Electricity Demand $211,394 15,244 kW-months/year $13.87
Electricity Fees $17,255 - $ -
Natural Gas $41,855 4,105 MMBtu $10.20
TOTAL ENERGY COSTS $540,470
RECOMMENDED SAVINGS* $192,770 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,753
Cost:
$500
$1,485 20,831 $1,173 84 $95 - $1,485
20,831
kWh
$1,173
84
kW-months/year
$95
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$9,693
Cost:
$8,473
$5,929 83,151 $3,429 247 $335 - $5,929
83,151
kWh
$3,429
247
kW-months/year
$335
-
$
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$178,998
Cost:
$1,000,734
$64,278 901,514 $108,533 7,825 $6,187 - $64,278
901,514
kWh
$108,533
7,825
kW-months/year
$6,187
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$531
Cost:
$1,463
$237 3,318 $276 20 $18 - $237
3,318
kWh
$276
20
kW-months/year
$18
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$688
Cost:
$3,738
$303 4,256 $361 26 $24 - $303
4,256
kWh
$361
26
kW-months/year
$24
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$107
Cost:
$452
$103 1,440 - - $4 - $103
1,440
kWh
-
-
kW-months/year
$4
-
$
TOTAL RECOMMENDED Savings:
$192,770
Cost:
$1,015,360
$72,335 1,014,510 $113,772 8,202 $6,663 - $72,335
1,014,510
kWh
$113,772
8,202
kW-months/year
$6,663
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees