Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2011 |
Principal Product | Diesel Engines |
NAICS | 336310 - Motor Vehicle Gasoline Engine and Engine Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $50,000,000-$100,000,000 |
# of Employees | 999 |
Plant Area (Sq.Ft.) | 544,000 |
Annual Production | 1,000 Units |
Production Hrs. Annual | 6,240 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,571,133 | 49,444,865 | kWh | $0.05 |
Electricity Demand | $693,252 | 94,064 | kW-months/year | $7.37 |
Natural Gas | $155,849 | 11,718 | MMBtu | $13.30 |
TOTAL ENERGY COSTS | $3,420,234 | |||
RECOMMENDED SAVINGS* | $657,177 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $105,208 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $78,640 Cost: $8,320 |
$39,260 | 755,000 | $10,466 | 1,420 | $28,914 | 2,174 |
$39,260 755,000 kWh |
$10,466 1,420 kW-months/year |
$28,914 2,174 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $71,901 Cost: $30,750 |
$66,300 | 1,275,000 | $5,601 | 760 | - | - |
$66,300 1,275,000 kWh |
$5,601 760 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS |
Savings: $72,048 Cost: $98,000 |
$49,348 | 949,000 | $22,700 | 3,080 | - | - |
$49,348 949,000 kWh |
$22,700 3,080 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,700 Cost: $60,860 |
$13,125 | 252,396 | $3,575 | 485 | - | - |
$13,125 252,396 kWh |
$3,575 485 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $20,767 Cost: $13,730 |
$20,767 | 399,360 | - | - | - | - |
$20,767 399,360 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7122 DISCONNECT BALLASTS |
Savings: $5,801 Cost: $405 |
$4,556 | 87,610 | $1,245 | 169 | - | - |
$4,556 87,610 kWh |
$1,245 169 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $29,663 Cost: $26,400 |
- | - | $29,663 | 4,025 | - | - |
- - kWh |
$29,663 4,025 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $92,285 Cost: $51,748 |
$72,519 | 1,394,593 | $19,766 | 2,682 | - | - |
$72,519 1,394,593 kWh |
$19,766 2,682 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $269,372 Cost: $630,225 |
$211,680 | 4,070,773 | $57,692 | 7,828 | - | - |
$211,680 4,070,773 kWh |
$57,692 7,828 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $657,177 Cost: $920,438 |
$477,555 | 9,183,732 | $150,708 | 20,449 | $28,914 | 2,174 | $477,555 9,183,732 kWh |
$150,708 20,449 kW-months/year |
$28,914 2,174 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $105,208 Cost: $22,455 |
$64,583 | 1,241,970 | $11,711 | 1,589 | $28,914 | 2,174 | $64,583 1,241,970 kWh |
$11,711 1,589 kW-months/year |
$28,914 2,174 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |