Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Connecticut |
---|---|
Assessment Year | 2022 |
Principal Product | Precision aerospace and medical components |
NAICS | 333612 - Speed Changer, Industrial High-Speed Drive, and Gear Manufacturing |
SIC | 3566 - Speed Changers, Drives, And Gears |
Sales | $50,000,000-$100,000,000 |
# of Employees | 230 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 5,500,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $261,495 | 2,540,170 | kWh | $0.10 |
Electricity Demand | $153,009 | 7,476 | kW-months/year | $20.47 |
Electricity Fees | $45,184 | - | $ | - |
Natural Gas | $37,551 | 2,490 | MMBtu | $15.08 |
TOTAL ENERGY COSTS | $497,239 | |||
RECOMMENDED SAVINGS* | $211,063 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $45,898 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $13,041 Cost: $56,085 |
$4,376 | 42,527 | $1,193 | 58 | - | - | - | - | $7,472 | - |
$4,376 42,527 kWh |
$1,193 58 kW-months/year |
- - $ |
- - $ |
$7,472 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,440 Cost: $15,982 |
$2,391 | 23,239 | $1,048 | 51 | - | - | - | - | - | - |
$2,391 23,239 kWh |
$1,048 51 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $20,036 Cost: $48,285 |
$12,816 | 124,552 | $7,369 | 360 | - | - | $613 | - | $(-763) | - |
$12,816 124,552 kWh |
$7,369 360 kW-months/year |
- - $ |
$613 - $ |
$(-763) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,728 Cost: $2,000 |
$4,909 | 47,711 | $819 | 40 | - | - | - | - | - | - |
$4,909 47,711 kWh |
$819 40 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,009 Cost: $4,000 |
$1,723 | 16,741 | $287 | 14 | - | - | - | - | - | - |
$1,723 16,741 kWh |
$287 14 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,185 Cost: $200 |
$1,017 | 9,884 | $168 | 8 | - | - | - | - | - | - |
$1,017 9,884 kWh |
$168 8 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $158,531 Cost: $626,592 |
$109,089 | 1,060,143 | $68,042 | 3,324 | - | - | - | - | $(-18,600) | - |
$109,089 1,060,143 kWh |
$68,042 3,324 kW-months/year |
- - $ |
- - $ |
$(-18,600) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $530 Cost: - |
- | - | - | - | $530 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$530 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $6,563 Cost: - |
- | - | - | - | $6,563 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,563 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $211,063 Cost: $753,144 |
$136,322 | 1,324,797 | $78,927 | 3,856 | $7,093 | - | $613 | - | $(-11,891) | - | $136,322 1,324,797 kWh |
$78,927 3,856 kW-months/year |
$7,093 - $ |
$613 - $ |
$(-11,891) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $45,898 Cost: $106,370 |
$22,102 | 214,790 | $9,381 | 458 | $7,093 | - | $613 | - | $6,709 | - | $22,102 214,790 kWh |
$9,381 458 kW-months/year |
$7,093 - $ |
$613 - $ |
$6,709 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes |