Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1982
Principal Product SOLENOIDS & SWITCHES
NAICS n/a
SIC 3679 - Electronic Components, Nec
Sales $10,000,000-$50,000,000
# of Employees 340
Plant Area (Sq.Ft.) 0
Annual Production 600,000 Pieces
Production Hrs. Annual 0
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $138,673 2,891,266 kWh $0.05
Natural Gas $14,635 4,357 MMBtu $3.36
TOTAL ENERGY COSTS $153,308
RECOMMENDED SAVINGS* $4,440 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7245 USE DIRECT AIR SUPPLY TO EXHAUST HOODS Savings:
$2,701
Cost:
$624
- - $2,701 624 -
-
kWh
$2,701
624
MMBtu
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$281
Cost:
$500
$281 5,862 - - $281
5,862
kWh
-
-
MMBtu
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$1,458
Cost:
-
$1,458 - - - $1,458
-
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$4,440
Cost:
$1,124
$1,739 5,862 $2,701 624 $1,739
5,862
kWh
$2,701
624
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas