IAC logo
IAC Assessment: UD0109
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UD0109
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1983
Principal Product ROPES AND TWINES
NAICS n/a
SIC 2298 - Cordage And Twine
Sales $10,000,000-$50,000,000
# of Employees 170
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 6,900
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $173,012 2,864,303 kWh $0.06
Natural Gas $157,872 28,162 MMBtu $5.61
TOTAL ENERGY COSTS $330,884
RECOMMENDED SAVINGS* $73,278 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $57,310
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$4,597
Cost:
$980
- - $4,597 766 -
-
kWh
$4,597
766
MMBtu
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$9,554
Cost:
$600
$9,554 135,404 - - $9,554
135,404
kWh
-
-
MMBtu
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$12,630
Cost:
$800
- - $12,630 2,104 -
-
kWh
$12,630
2,104
MMBtu
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$16,051
Cost:
$40,000
$(-3,534) (-50,117) $19,585 3,262 $(-3,534)
(-50,117)
kWh
$19,585
3,262
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,827
Cost:
$6,843
$9,686 145,369 $(-1,859) (-310) $9,686
145,369
kWh
$(-1,859)
(-310)
MMBtu
06: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$15,968
Cost:
$61,880
- - $15,968 2,660 -
-
kWh
$15,968
2,660
MMBtu
07: 2.7441 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH Savings:
$6,651
Cost:
$5,475
- - $6,651 1,108 -
-
kWh
$6,651
1,108
MMBtu
TOTAL RECOMMENDED Savings:
$73,278
Cost:
$116,578
$15,706 230,656 $57,572 9,590 $15,706
230,656
kWh
$57,572
9,590
MMBtu
TOTAL IMPLEMENTED Savings:
$57,310
Cost:
$54,698
$15,706 230,656 $41,604 6,930 $15,706
230,656
kWh
$41,604
6,930
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas