Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1992
Principal Product STEEL DOORS
NAICS n/a
SIC 3442 - Metal Doors, Sash, And Trim
Sales $50,000,000-$100,000,000
# of Employees 200
Plant Area (Sq.Ft.) 0
Annual Production 730,000 Pieces
Production Hrs. Annual 8,300
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $257,078 4,893,904 kWh $0.05
TOTAL ENERGY COSTS $257,078
RECOMMENDED SAVINGS* $73,254 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $72,363
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.3511 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS Savings:
$23,256
Cost:
$55,000
$23,256 - - - $23,256
-
kWh
-
-
MMBtu
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$35,120
Cost:
$38,000
$62,874 1,258,793 $(-27,754) (-6,608) $62,874
1,258,793
kWh
$(-27,754)
(-6,608)
MMBtu
03: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY Savings:
$4,668
Cost:
-
$5,425 253,517 $(-757) (-180) $5,425
253,517
kWh
$(-757)
(-180)
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,850
Cost:
$1,000
$696 32,532 $1,154 275 $696
32,532
kWh
$1,154
275
MMBtu
05: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$4,875
Cost:
$2,000
$4,875 94,959 - - $4,875
94,959
kWh
-
-
MMBtu
06: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$891
Cost:
-
$891 13,775 - - $891
13,775
kWh
-
-
MMBtu
07: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$2,594
Cost:
$1,000
- - $2,594 618 -
-
kWh
$2,594
618
MMBtu
TOTAL RECOMMENDED Savings:
$73,254
Cost:
$97,000
$98,017 1,653,576 $(-24,763) (-5,895) $98,017
1,653,576
kWh
$(-24,763)
(-5,895)
MMBtu
TOTAL IMPLEMENTED Savings:
$72,363
Cost:
$97,000
$97,126 1,639,801 $(-24,763) (-5,895) $97,126
1,639,801
kWh
$(-24,763)
(-5,895)
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas