Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1993
Principal Product weatherstripping, moldings, weatherseals
NAICS n/a
SIC 3429 - Hardware, Nec
Sales $10,000,000-$50,000,000
# of Employees 320
Plant Area (Sq.Ft.) 192,000
Annual Production 0 Units
Production Hrs. Annual 6,000
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $331,616 6,519,930 kWh $0.05
Natural Gas $10,630 2,628 MMBtu $4.04
TOTAL ENERGY COSTS $342,246
RECOMMENDED SAVINGS* $47,774 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,718
#|Description Savings
Cost
Status Electricity Usage Natural Gas Other Energy Electricity Usage Natural Gas Other Energy
$ kWh $ MMBtu $ MMBtu
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$16,277
Cost:
-
$16,277 - - - - - $16,277
-
kWh
-
-
MMBtu
-
-
MMBtu
02: 2.5123 REDUCE FLUID FLOW RATES Savings:
$7,396
Cost:
$5,000
$(-1,410) (-29,894) - - $8,806 275 $(-1,410)
(-29,894)
kWh
-
-
MMBtu
$8,806
275
MMBtu
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$12,240
Cost:
$40,000
- - $12,240 2,400 - - -
-
kWh
$12,240
2,400
MMBtu
-
-
MMBtu
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$156
Cost:
$200
$334 15,533 $(-178) (-35) - - $334
15,533
kWh
$(-178)
(-35)
MMBtu
-
-
MMBtu
05: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$6,539
Cost:
-
$6,539 63,013 - - - - $6,539
63,013
kWh
-
-
MMBtu
-
-
MMBtu
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$5,166
Cost:
$800
$6,665 155,041 $(-1,499) (-294) - - $6,665
155,041
kWh
$(-1,499)
(-294)
MMBtu
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$47,774
Cost:
$46,000
$28,405 203,693 $10,563 2,071 $8,806 275 $28,405
203,693
kWh
$10,563
2,071
MMBtu
$8,806
275
MMBtu
TOTAL IMPLEMENTED Savings:
$12,718
Cost:
$6,000
$5,589 140,680 $(-1,677) (-329) $8,806 275 $5,589
140,680
kWh
$(-1,677)
(-329)
MMBtu
$8,806
275
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu