Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1996 |
Principal Product | residential roofing |
NAICS | n/a |
SIC | 2952 - Asphalt Felts And Coatings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 135,300 |
Annual Production | 150,000 Tons |
Production Hrs. Annual | 8,500 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $156,798 | 5,751,172 | kWh | $0.03 |
Electricity Demand | $130,643 | 10,788 | kW-months/year | $12.11 |
Natural Gas | $271,801 | 109,909 | MMBtu | $2.47 |
TOTAL ENERGY COSTS | $559,242 | |||
RECOMMENDED SAVINGS* | $65,365 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $54,101 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1232 KEEP BOILER TUBES CLEAN |
Savings: $2,375 Cost: $500 |
- | - | - | - | $2,375 | 950 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,375 950 MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $10,368 Cost: $9,000 |
- | - | - | - | $4,168 | 1,667 | - | - | $6,200 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,168 1,667 MMBtu |
- - Tgal |
$6,200 - gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $14,952 Cost: $2,500 |
$6,248 | 297,479 | $6,579 | 420 | - | - | - | - | - | - | - | - | $2,125 | - |
$6,248 297,479 kWh |
$6,579 420 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
$2,125 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,741 Cost: $1,375 |
$445 | 21,102 | $1,026 | 66 | - | - | - | - | - | - | $270 | - | - | - |
$445 21,102 kWh |
$1,026 66 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
$270 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,907 Cost: $15,000 |
$2,088 | 99,355 | $2,199 | 140 | - | - | - | - | - | - | $620 | - | - | - |
$2,088 99,355 kWh |
$2,199 140 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
$620 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,431 Cost: $5,975 |
$1,018 | 48,359 | $1,078 | 68 | - | - | - | - | - | - | $335 | - | - | - |
$1,018 48,359 kWh |
$1,078 68 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
$335 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,554 Cost: $5,953 |
$797 | 38,101 | $1,757 | 112 | - | - | - | - | - | - | - | - | - | - |
$797 38,101 kWh |
$1,757 112 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $11,264 Cost: $45,000 |
$(-1,940) | (-92,321) | $(-2,256) | (-144) | - | - | $15,960 | 11,369,600 | - | - | $(-500) | - | - | - |
$(-1,940) (-92,321) kWh |
$(-2,256) (-144) kW-months/year |
- - MMBtu |
$15,960 11,369,600 Tgal |
- - gal |
$(-500) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $14,773 Cost: $34,000 |
$(-563) | (-25,498) | $(-564) | (-36) | - | - | $18,900 | 13,464,000 | - | - | $(-3,000) | - | - | - |
$(-563) (-25,498) kWh |
$(-564) (-36) kW-months/year |
- - MMBtu |
$18,900 13,464,000 Tgal |
- - gal |
$(-3,000) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $65,365 Cost: $119,303 |
$8,093 | 386,577 | $9,819 | 626 | $6,543 | 2,617 | $34,860 | 24,833,600 | $6,200 | - | $(-2,275) | - | $2,125 | - | $8,093 386,577 kWh |
$9,819 626 kW-months/year |
$6,543 2,617 MMBtu |
$34,860 24,833,600 Tgal |
$6,200 - gal |
$(-2,275) - $ |
$2,125 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $54,101 Cost: $74,303 |
$10,033 | 478,898 | $12,075 | 770 | $6,543 | 2,617 | $18,900 | 13,464,000 | $6,200 | - | $(-1,775) | - | $2,125 | - | $10,033 478,898 kWh |
$12,075 770 kW-months/year |
$6,543 2,617 MMBtu |
$18,900 13,464,000 Tgal |
$6,200 - gal |
$(-1,775) - $ |
$2,125 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Administrative Changes | Ancillary Material Cost |