Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1997 |
Principal Product | sheet metal work, stampings |
NAICS | n/a |
SIC | 3444 - Sheet Metalwork |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 69,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 7,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $42,964 | 2,027,257 | kWh | $0.02 |
Electricity Demand | $52,987 | 380 | kW-months/year | $139.44 |
Natural Gas | $110,415 | 20,646 | MMBtu | $5.35 |
TOTAL ENERGY COSTS | $206,366 | |||
RECOMMENDED SAVINGS* | $31,620 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,098 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $5,469 Cost: - |
$2,820 | 133,060 | $2,649 | 228 | - | - | - | - | - | - | - | - |
$2,820 133,060 kWh |
$2,649 228 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,083 Cost: $15,018 |
$1,921 | 90,563 | $3,162 | 276 | - | - | - | - | - | - | - | - |
$1,921 90,563 kWh |
$3,162 276 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,422 Cost: $637 |
$711 | 33,411 | $711 | 61 | - | - | - | - | - | - | - | - |
$711 33,411 kWh |
$711 61 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $123 Cost: $2,000 |
$62 | 2,052 | $61 | 5 | - | - | - | - | - | - | - | - |
$62 2,052 kWh |
$61 5 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.3133 USE OTHER WASTE CONCENTRATION METHODS |
Savings: $580 Cost: - |
- | - | - | - | - | - | $486 | 2,700 | - | - | $94 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$486 2,700 gal |
- - $ |
$94 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY |
Savings: $6,335 Cost: $5,000 |
- | - | - | - | $6,335 | 1,167 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,335 1,167 MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2424 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS |
Savings: $10,100 Cost: $20,000 |
- | - | - | - | $10,100 | 1,860 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,100 1,860 MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $2,508 Cost: $4,880 |
- | - | - | - | - | - | - | - | $2,508 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$2,508 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,620 Cost: $47,535 |
$5,514 | 259,086 | $6,583 | 570 | $16,435 | 3,027 | $486 | 2,700 | $2,508 | - | $94 | - | $5,514 259,086 kWh |
$6,583 570 kW-months/year |
$16,435 3,027 MMBtu |
$486 2,700 gal |
$2,508 - $ |
$94 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,098 Cost: $26,898 |
$4,803 | 225,675 | $5,872 | 509 | $6,335 | 1,167 | $486 | 2,700 | $2,508 | - | $94 | - | $4,803 225,675 kWh |
$5,872 509 kW-months/year |
$6,335 1,167 MMBtu |
$486 2,700 gal |
$2,508 - $ |
$94 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes |