Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1998 |
Principal Product | Jigs fixtures,tools and die machinery |
NAICS | n/a |
SIC | 3544 - Special Dies, Tools, Jigs & Fixtures |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 50,000 Pieces |
Production Hrs. Annual | 3,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $33,055 | 1,271,688 | kWh | $0.03 |
Electricity Demand | $62,977 | 4,476 | kW-months/year | $14.07 |
Natural Gas | $13,704 | 2,779 | MMBtu | $4.93 |
TOTAL ENERGY COSTS | $112,747 | |||
RECOMMENDED SAVINGS* | $15,280 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $12,225 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.3128 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS |
Savings: $2,243 Cost: - |
- | - | - | - | - | - | $630 | 300 | $(-825) | - | - | - | $2,438 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$630 300 gal |
$(-825) - $ |
- - $ |
$2,438 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.5125 SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE |
Savings: $7,607 Cost: $720 |
$744 | 28,722 | $1,604 | 114 | - | - | - | - | - | - | $5,259 | - | - | - |
$744 28,722 kWh |
$1,604 114 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
$5,259 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $2,274 Cost: $300 |
$640 | 24,619 | $1,384 | 98 | - | - | - | - | - | - | $250 | - | - | - |
$640 24,619 kWh |
$1,384 98 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
$250 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $2,375 Cost: $1,120 |
$751 | 29,015 | $1,624 | 115 | - | - | - | - | - | - | - | - | - | - |
$751 29,015 kWh |
$1,624 115 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $781 Cost: $2,000 |
$153 | 5,862 | - | - | $628 | 128 | - | - | - | - | - | - | - | - |
$153 5,862 kWh |
- - kW-months/year |
$628 128 MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $15,280 Cost: $4,140 |
$2,288 | 88,218 | $4,612 | 327 | $628 | 128 | $630 | 300 | $(-825) | - | $5,509 | - | $2,438 | - | $2,288 88,218 kWh |
$4,612 327 kW-months/year |
$628 128 MMBtu |
$630 300 gal |
$(-825) - $ |
$5,509 - $ |
$2,438 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $12,225 Cost: $1,840 |
$1,495 | 57,737 | $3,228 | 229 | - | - | $630 | 300 | $(-825) | - | $5,259 | - | $2,438 | - | $1,495 57,737 kWh |
$3,228 229 kW-months/year |
- - MMBtu |
$630 300 gal |
$(-825) - $ |
$5,259 - $ |
$2,438 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost |