Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1998 |
Principal Product | Die sets for can tooling |
NAICS | n/a |
SIC | 3544 - Special Dies, Tools, Jigs & Fixtures |
Sales | $1,000,000-$5,000,000 |
# of Employees | 43 |
Plant Area (Sq.Ft.) | 13,000 |
Annual Production | 4,800 Pieces |
Production Hrs. Annual | 6,600 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $20,096 | 773,154 | kWh | $0.03 |
Electricity Demand | $24,482 | 1,740 | kW-months/year | $14.07 |
Natural Gas | $1,419 | 271 | MMBtu | $5.24 |
TOTAL ENERGY COSTS | $47,807 | |||
RECOMMENDED SAVINGS* | $342,009 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,042 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.112 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL |
Savings: $322,350 Cost: $250,000 |
- | - | - | - | - | - | - | - | $35,700 | - | - | - | $286,650 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$35,700 - $ |
- - $ |
$286,650 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.432 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME |
Savings: $12,682 Cost: - |
- | - | - | - | - | - | - | - | $12,682 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$12,682 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.3128 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS |
Savings: $3,343 Cost: $1,000 |
- | - | - | - | - | - | $225 | - | $306 | - | $2,812 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$225 - gal |
$306 - $ |
$2,812 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,070 Cost: $3,903 |
$1,043 | 40,152 | $1,027 | 73 | - | - | - | - | - | - | - | - | - | - |
$1,043 40,152 kWh |
$1,027 73 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $736 Cost: - |
$736 | 28,429 | - | - | - | - | - | - | - | - | - | - | - | - |
$736 28,429 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $624 Cost: $500 |
- | - | - | - | $624 | 120 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$624 120 MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $204 Cost: $250 |
$103 | 4,103 | $101 | 7 | - | - | - | - | - | - | - | - | - | - |
$103 4,103 kWh |
$101 7 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $342,009 Cost: $255,653 |
$1,882 | 72,684 | $1,128 | 80 | $624 | 120 | $225 | - | $48,688 | - | $2,812 | - | $286,650 | - | $1,882 72,684 kWh |
$1,128 80 kW-months/year |
$624 120 MMBtu |
$225 - gal |
$48,688 - $ |
$2,812 - $ |
$286,650 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,042 Cost: $500 |
$736 | 28,429 | - | - | $624 | 120 | - | - | $12,682 | - | - | - | - | - | $736 28,429 kWh |
- - kW-months/year |
$624 120 MMBtu |
- - gal |
$12,682 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Primary Raw Material |