Assessment Year | 1999 |
Principal Product | electronic measuring equipment and sensors |
NAICS | n/a |
SIC | 3823 - Process Control Instruments |
Sales | $10,000,000-$50,000,000 |
# of Employees | 230 |
Plant Area (Sq.Ft.) | 110,000 |
Annual Production | 31,250 Pieces |
Production Hrs. Annual | 3,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $109,304 | 3,440,211 | kWh | $0.03 |
Electricity Demand | $53,664 | 8,256 | kW-months/year | $6.50 |
Natural Gas | $8,312 | 1,635 | MMBtu | $5.08 |
TOTAL ENERGY COSTS | $186,661 | |||
RECOMMENDED SAVINGS* | $22,193 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,171 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $8,393 Cost: $3,600 |
- | - | - | - | - | - | $3,393 | 715 | - | - | - | - | - | - | $5,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,393 715 gal |
- - lb |
- - $ |
- - $ |
$5,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $5,475 Cost: $7,000 |
- | - | - | - | - | - | - | - | $3,375 | 150,000 | $(-1,500) | - | $3,600 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$3,375 150,000 lb |
$(-1,500) - $ |
$3,600 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7242 CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES |
Savings: $5,171 Cost: $4,000 |
$906 | 28,429 | - | - | $4,265 | 853 | - | - | - | - | - | - | - | - | - | - |
$906 28,429 kWh |
- - kW-months/year |
$4,265 853 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,154 Cost: $2,000 |
$1,814 | 56,565 | $1,340 | 206 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,814 56,565 kWh |
$1,340 206 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $22,193 Cost: $16,600 |
$2,720 | 84,994 | $1,340 | 206 | $4,265 | 853 | $3,393 | 715 | $3,375 | 150,000 | $(-1,500) | - | $3,600 | - | $5,000 | - | $2,720 84,994 kWh |
$1,340 206 kW-months/year |
$4,265 853 MMBtu |
$3,393 715 gal |
$3,375 150,000 lb |
$(-1,500) - $ |
$3,600 - $ |
$5,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,171 Cost: $4,000 |
$906 | 28,429 | - | - | $4,265 | 853 | - | - | - | - | - | - | - | - | - | - | $906 28,429 kWh |
- - kW-months/year |
$4,265 853 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost |