Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2000 |
Principal Product | Food products |
NAICS | n/a |
SIC | 2026 - Fluid Milk |
Sales | $50,000,000-$100,000,000 |
# of Employees | 190 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 364,000,000 Pounds |
Production Hrs. Annual | 7,488 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $230,401 | 7,073,857 | kWh | $0.03 |
Electricity Demand | $288,179 | 15,696 | kW-months/year | $18.36 |
Natural Gas | $93,182 | 26,022 | MMBtu | $3.58 |
TOTAL ENERGY COSTS | $843,307 | |||
RECOMMENDED SAVINGS* | $676,616 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $23,837 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Water Consumption | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Water Consumption | Primary Product | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | $ | Tgal | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $454,896 Cost: $340,000 |
- | - | - | - | - | - | $219,024 | - | - | - | - | - | - | - | $235,872 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$219,024 - $ |
- - $ |
- - $ |
- - Tgal |
$235,872 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4131 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT |
Savings: $99,635 Cost: $350,000 |
- | - | - | - | $(-9,967) | - | $(-12,012) | - | $148,134 | - | $(-26,520) | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$(-9,967) - $ |
$(-12,012) - $ |
$148,134 - $ |
$(-26,520) - $ |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $96,665 Cost: $5,000 |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | $96,665 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - Tgal |
- - $ |
$96,665 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4151 MINIMIZE WATER USAGE |
Savings: $18,654 Cost: $298 |
- | - | - | - | - | - | - | - | - | - | - | - | $18,654 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
$18,654 - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $5,183 Cost: - |
$1,679 | 72,978 | $3,504 | 156 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$1,679 72,978 kWh |
$3,504 156 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $1,583 Cost: - |
$383 | 18,171 | $1,200 | 53 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$383 18,171 kWh |
$1,200 53 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $676,616 Cost: $695,298 |
$2,062 | 91,149 | $4,704 | 209 | $(-9,967) | - | $207,012 | - | $148,134 | - | $(-26,520) | - | $18,654 | - | $235,872 | - | $96,665 | - | $2,062 91,149 kWh |
$4,704 209 kW-months/year |
$(-9,967) - $ |
$207,012 - $ |
$148,134 - $ |
$(-26,520) - $ |
$18,654 - Tgal |
$235,872 - $ |
$96,665 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $23,837 Cost: $298 |
$1,679 | 72,978 | $3,504 | 156 | - | - | - | - | - | - | - | - | $18,654 | - | - | - | - | - | $1,679 72,978 kWh |
$3,504 156 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
$18,654 - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | $ | Tgal | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Water Consumption | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Water Consumption | Primary Product | Increase in Production |