Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2000 |
Principal Product | commercial printed products |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $5,000,000-$10,000,000 |
# of Employees | 51 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 7 Thousand Gallons |
Production Hrs. Annual | 6,864 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $30,325 | 1,117,819 | kWh | $0.03 |
Electricity Demand | $41,647 | 2,960 | kW-months/year | $14.07 |
Natural Gas | $9,280 | 1,413 | MMBtu | $6.57 |
TOTAL ENERGY COSTS | $81,252 | |||
RECOMMENDED SAVINGS* | $983,327 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $407,698 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.453 RESCHEDULE BREAKS TO ALLOW FOR CONTINUOUS PRODUCTION |
Savings: $374,400 Cost: - |
- | - | - | - | $374,400 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$374,400 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.112 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL |
Savings: $365,350 Cost: $1,000,000 |
- | - | - | - | $43,600 | - | - | - | $321,750 | - |
- - kWh |
- - kW-months/year |
$43,600 - $ |
- - $ |
$321,750 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $195,104 Cost: $6,720 |
- | - | - | - | $195,104 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$195,104 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.112 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL |
Savings: $32,550 Cost: - |
- | - | - | - | - | - | $32,550 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$32,550 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,175 Cost: $39,298 |
$7,304 | 347,890 | $7,871 | 631 | - | - | - | - | - | - |
$7,304 347,890 kWh |
$7,871 631 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $748 Cost: $360 |
$479 | 17,878 | $269 | 19 | - | - | - | - | - | - |
$479 17,878 kWh |
$269 19 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $983,327 Cost: $1,046,378 |
$7,783 | 365,768 | $8,140 | 650 | $613,104 | - | $32,550 | - | $321,750 | - | $7,783 365,768 kWh |
$8,140 650 kW-months/year |
$613,104 - $ |
$32,550 - $ |
$321,750 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $407,698 Cost: $360 |
$479 | 17,878 | $269 | 19 | $374,400 | - | $32,550 | - | - | - | $479 17,878 kWh |
$269 19 kW-months/year |
$374,400 - $ |
$32,550 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Increase in Production |