IAC logo
IAC Assessment: UD0607
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UD0607
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2000
Principal Product rubber chemicals
NAICS n/a
SIC 2899 - Chemical Preparations, Nec
Sales $50,000,000-$100,000,000
# of Employees 77
Plant Area (Sq.Ft.) 58,000
Annual Production 46,000,000 Pounds
Production Hrs. Annual 8,736
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $141,198 5,022,567 kWh $0.03
Electricity Demand $146,791 10,068 kW-months/year $14.58
LPG $173,031 41,725 MMBtu $4.15
TOTAL ENERGY COSTS $559,333
RECOMMENDED SAVINGS* $63,638 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,472
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
01: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION Savings:
$38,566
Cost:
$50,000
- - - - - - $48,566 4,457,660 $(-10,000) - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$48,566
4,457,660
Tgal
$(-10,000)
-
$
02: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$16,600
Cost:
$20,000
- - - - $16,600 4,000 - - - - -
-
kWh
-
-
kW-months/year
$16,600
4,000
MMBtu
-
-
Tgal
-
-
$
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$3,566
Cost:
-
$3,146 108,441 $420 29 - - - - - - $3,146
108,441
kWh
$420
29
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,478
Cost:
$7,485
$1,610 55,686 $1,868 127 - - - - - - $1,610
55,686
kWh
$1,868
127
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,428
Cost:
$3,135
- - - - $1,428 344 - - - - -
-
kWh
-
-
kW-months/year
$1,428
344
MMBtu
-
-
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$63,638
Cost:
$80,620
$4,756 164,127 $2,288 156 $18,028 4,344 $48,566 4,457,660 $(-10,000) - $4,756
164,127
kWh
$2,288
156
kW-months/year
$18,028
4,344
MMBtu
$48,566
4,457,660
Tgal
$(-10,000)
-
$
TOTAL IMPLEMENTED Savings:
$8,472
Cost:
$10,620
$4,756 164,127 $2,288 156 $1,428 344 - - - - $4,756
164,127
kWh
$2,288
156
kW-months/year
$1,428
344
MMBtu
-
-
Tgal
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes