Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2001 |
Principal Product | Thin Film Color Coating on and in Glass |
NAICS | n/a |
SIC | 3231 - Products Of Purchased Glass |
Sales | $1,000,000-$5,000,000 |
# of Employees | 45 |
Plant Area (Sq.Ft.) | 35,850 |
Annual Production | 10,000,000 Pieces |
Production Hrs. Annual | 4,800 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $37,593 | 1,555,920 | kWh | $0.02 |
Electricity Demand | $84,420 | 6,000 | kW-months/year | $14.07 |
Natural Gas | $46,142 | 7,867 | MMBtu | $5.87 |
TOTAL ENERGY COSTS | $168,155 | |||
RECOMMENDED SAVINGS* | $358,590 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $59,436 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $277,500 Cost: $100,000 |
- | - | - | - | - | - | $201,600 | - | $75,900 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$201,600 - $ |
$75,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $53,184 Cost: $30,570 |
- | - | - | - | - | - | $29,888 | - | $23,296 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$29,888 - $ |
$23,296 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $11,618 Cost: $23,000 |
$(-1,137) | (-49,440) | $(-1,739) | (-124) | $14,494 | 2,995,392 | - | - | - | - |
$(-1,137) (-49,440) kWh |
$(-1,739) (-124) kW-months/year |
$14,494 2,995,392 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $10,036 Cost: - |
- | - | $12,916 | 924 | - | - | $(-2,880) | - | - | - |
- - kWh |
$12,916 924 kW-months/year |
- - Tgal |
$(-2,880) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $6,252 Cost: - |
$1,339 | 58,200 | $4,913 | 349 | - | - | - | - | - | - |
$1,339 58,200 kWh |
$4,913 349 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $358,590 Cost: $153,570 |
$202 | 8,760 | $16,090 | 1,149 | $14,494 | 2,995,392 | $228,608 | - | $99,196 | - | $202 8,760 kWh |
$16,090 1,149 kW-months/year |
$14,494 2,995,392 Tgal |
$228,608 - $ |
$99,196 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $59,436 Cost: $30,570 |
$1,339 | 58,200 | $4,913 | 349 | - | - | $29,888 | - | $23,296 | - | $1,339 58,200 kWh |
$4,913 349 kW-months/year |
- - Tgal |
$29,888 - $ |
$23,296 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Primary Product |