Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2001 |
Principal Product | Metal stamping and welding assemblies |
NAICS | n/a |
SIC | 3469 - Metal Stampings, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 330 |
Plant Area (Sq.Ft.) | 208,000 |
Annual Production | 50,000,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $155,213 | 6,101,280 | kWh | $0.03 |
Electricity Demand | $141,521 | 12,948 | kW-months/year | $10.93 |
Natural Gas | $138,065 | 23,083 | MMBtu | $5.98 |
TOTAL ENERGY COSTS | $434,799 | |||
RECOMMENDED SAVINGS* | $1,240,809 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,209,312 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $324,000 Cost: $1,600,000 |
- | - | - | - | - | - | $324,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$324,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.625 DEVELOP STANDARD OPERATING PROCEDURES |
Savings: $708,750 Cost: $350,000 |
- | - | - | - | $708,750 | - | - | - |
- - kWh |
- - kW-months/year |
$708,750 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.625 DEVELOP STANDARD OPERATING PROCEDURES |
Savings: $162,000 Cost: $48,000 |
- | - | - | - | $162,000 | - | - | - |
- - kWh |
- - kW-months/year |
$162,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $19,834 Cost: $12,680 |
- | - | - | - | $19,834 | - | - | - |
- - kWh |
- - kW-months/year |
$19,834 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $6,067 Cost: $7,000 |
$3,510 | 117,000 | $2,557 | 468 | - | - | - | - |
$3,510 117,000 kWh |
$2,557 468 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $9,670 Cost: $3,680 |
$1,800 | 60,000 | $7,870 | 720 | - | - | - | - |
$1,800 60,000 kWh |
$7,870 720 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,361 Cost: $588 |
$1,787 | 59,570 | $1,574 | 144 | - | - | - | - |
$1,787 59,570 kWh |
$1,574 144 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $2,800 Cost: $960 |
$1,620 | 54,000 | $1,180 | 108 | - | - | - | - |
$1,620 54,000 kWh |
$1,180 108 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,671 Cost: - |
$1,980 | 66,000 | $1,443 | 132 | $(-1,752) | - | - | - |
$1,980 66,000 kWh |
$1,443 132 kW-months/year |
$(-1,752) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $904 Cost: - |
- | - | $2,304 | 211 | $(-1,400) | - | - | - |
- - kWh |
$2,304 211 kW-months/year |
$(-1,400) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $797 Cost: $1,168 |
$797 | 26,583 | - | - | - | - | - | - |
$797 26,583 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $534 Cost: $680 |
$216 | 7,200 | $318 | 29 | - | - | - | - |
$216 7,200 kWh |
$318 29 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $421 Cost: $688 |
$421 | 14,025 | - | - | - | - | - | - |
$421 14,025 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,240,809 Cost: $2,025,444 |
$12,131 | 404,378 | $17,246 | 1,812 | $887,432 | - | $324,000 | - | $12,131 404,378 kWh |
$17,246 1,812 kW-months/year |
$887,432 - $ |
$324,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,209,312 Cost: $2,003,328 |
$5,821 | 194,025 | $10,493 | 960 | $868,998 | - | $324,000 | - | $5,821 194,025 kWh |
$10,493 960 kW-months/year |
$868,998 - $ |
$324,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||