Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2002 |
Principal Product | Plastic Blow Molding |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 95,000 |
Annual Production | 7,500,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $193,926 | 5,185,200 | kWh | $0.04 |
Electricity Demand | $87,544 | 12,696 | kW-months/year | $6.90 |
Natural Gas | $32,980 | 3,312 | MMBtu | $9.96 |
TOTAL ENERGY COSTS | $320,335 | |||
RECOMMENDED SAVINGS* | $52,267 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,996 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $18,752 Cost: $4,500 |
- | - | - | - | - | - | $12,480 | - | $112 | - | $6,160 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$12,480 - $ |
$112 - $ |
$6,160 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $17,379 Cost: $45,000 |
$12,329 | 329,659 | $5,050 | 704 | - | - | - | - | - | - | - | - |
$12,329 329,659 kWh |
$5,050 704 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $6,156 Cost: $1,323 |
$6,156 | 164,600 | - | - | - | - | - | - | - | - | - | - |
$6,156 164,600 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $2,749 Cost: $2,500 |
- | - | - | - | $2,749 | 993,477 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,749 993,477 Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,235 Cost: $7,600 |
$1,633 | 43,680 | $602 | 84 | - | - | - | - | - | - | - | - |
$1,633 43,680 kWh |
$602 84 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,108 Cost: $196 |
$1,540 | 41,184 | $568 | 79 | - | - | - | - | - | - | - | - |
$1,540 41,184 kWh |
$568 79 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,899 Cost: $5,800 |
$1,340 | 35,828 | $559 | 78 | - | - | - | - | - | - | - | - |
$1,340 35,828 kWh |
$559 78 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $989 Cost: $2,502 |
$723 | 19,344 | $266 | 37 | - | - | - | - | - | - | - | - |
$723 19,344 kWh |
$266 37 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $52,267 Cost: $69,421 |
$23,721 | 634,295 | $7,045 | 982 | $2,749 | 993,477 | $12,480 | - | $112 | - | $6,160 | - | $23,721 634,295 kWh |
$7,045 982 kW-months/year |
$2,749 993,477 Tgal |
$12,480 - $ |
$112 - $ |
$6,160 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,996 Cost: $8,498 |
$3,603 | 96,356 | $1,393 | 194 | - | - | - | - | - | - | - | - | $3,603 96,356 kWh |
$1,393 194 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Primary Product |