Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2005
Principal Product Automotive Lifts
NAICS 333921 - Elevator and Moving Stairway Manufacturing
SIC 3534 - Elevators And Moving Stairways
Sales $100,000,000-$500,000,000
# of Employees 450
Plant Area (Sq.Ft.) 170,000
Annual Production 28,000 Pieces
Production Hrs. Annual 6,000
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $138,086 7,485,098 kWh $0.02
Electricity Demand $268,541 19,056 kW-months/year $14.09
Natural Gas $371,568 43,853 MMBtu $8.47
TOTAL ENERGY COSTS $787,652
RECOMMENDED SAVINGS* $152,299 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $33,798
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.3511 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS Savings:
$59,198
Cost:
$30,000
- - - - $59,198 7,193 - - -
-
kWh
-
-
kW-months/year
$59,198
7,193
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$33,240
Cost:
$102,000
$14,380 846,000 $17,210 1,692 - - $1,650 - $14,380
846,000
kWh
$17,210
1,692
kW-months/year
-
-
MMBtu
$1,650
-
$
03: 2.7134 USE PHOTOCELL CONTROLS Savings:
$16,400
Cost:
-
- - - - $16,400 1,991 - - -
-
kWh
-
-
kW-months/year
$16,400
1,991
MMBtu
-
-
$
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$13,563
Cost:
$6,505
- - - - $13,563 1,648 - - -
-
kWh
-
-
kW-months/year
$13,563
1,648
MMBtu
-
-
$
05: 2.7262 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS Savings:
$9,550
Cost:
$530
- - - - $9,550 1,160 - - -
-
kWh
-
-
kW-months/year
$9,550
1,160
MMBtu
-
-
$
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$6,922
Cost:
$4,800
$1,800 90,000 $5,122 360 - - - - $1,800
90,000
kWh
$5,122
360
kW-months/year
-
-
MMBtu
-
-
$
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$4,199
Cost:
$7,500
$784 39,200 $3,415 240 - - - - $784
39,200
kWh
$3,415
240
kW-months/year
-
-
MMBtu
-
-
$
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$3,477
Cost:
-
$1,565 93,825 $1,912 192 - - - - $1,565
93,825
kWh
$1,912
192
kW-months/year
-
-
MMBtu
-
-
$
09: 2.7316 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN Savings:
$3,364
Cost:
-
$1,530 90,000 $1,834 180 - - - - $1,530
90,000
kWh
$1,834
180
kW-months/year
-
-
MMBtu
-
-
$
10: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,915
Cost:
-
$778 45,800 $1,137 108 - - - - $778
45,800
kWh
$1,137
108
kW-months/year
-
-
MMBtu
-
-
$
11: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$471
Cost:
$880
$175 10,313 $296 72 - - - - $175
10,313
kWh
$296
72
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$152,299
Cost:
$152,215
$21,012 1,215,138 $30,926 2,844 $98,711 11,992 $1,650 - $21,012
1,215,138
kWh
$30,926
2,844
kW-months/year
$98,711
11,992
MMBtu
$1,650
-
$
TOTAL IMPLEMENTED Savings:
$33,798
Cost:
$7,385
$1,705 100,313 $2,130 252 $29,963 3,639 - - $1,705
100,313
kWh
$2,130
252
kW-months/year
$29,963
3,639
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost