Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2005 |
Principal Product | Automobile Parts and Accessories/Appliance Products |
NAICS | 332322 - Sheet Metal Work Manufacturing |
SIC | 3444 - Sheet Metalwork |
Sales | $100,000,000-$500,000,000 |
# of Employees | 600 |
Plant Area (Sq.Ft.) | 447,100 |
Annual Production | 36,943,475 Pieces |
Production Hrs. Annual | 8,112 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $508,141 | 19,622,585 | kWh | $0.03 |
Electricity Demand | $485,103 | 37,956 | kW-months/year | $12.78 |
Natural Gas | $1,405,144 | 187,528 | MMBtu | $7.49 |
TOTAL ENERGY COSTS | $2,526,002 | |||
RECOMMENDED SAVINGS* | $569,102 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $39,166 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.625 DEVELOP STANDARD OPERATING PROCEDURES |
Savings: $256,000 Cost: $110,000 |
- | - | - | - | - | - | $256,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$256,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $113,219 Cost: $13,700 |
- | - | - | - | $113,219 | 15,116 | - | - |
- - kWh |
- - kW-months/year |
$113,219 15,116 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $99,594 Cost: - |
- | - | - | - | $99,594 | 13,297 | - | - |
- - kWh |
- - kW-months/year |
$99,594 13,297 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $55,514 Cost: - |
$30,076 | 1,115,770 | $22,246 | 1,716 | - | - | $3,192 | - |
$30,076 1,115,770 kWh |
$22,246 1,716 kW-months/year |
- - MMBtu |
$3,192 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $19,115 Cost: - |
$19,115 | 735,186 | - | - | - | - | - | - |
$19,115 735,186 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $11,374 Cost: $1,725 |
$6,538 | 251,472 | $4,836 | 372 | - | - | - | - |
$6,538 251,472 kWh |
$4,836 372 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7122 DISCONNECT BALLASTS |
Savings: $8,190 Cost: $2,250 |
$4,708 | 181,076 | $3,482 | 264 | - | - | - | - |
$4,708 181,076 kWh |
$3,482 264 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,187 Cost: $4,650 |
$1,691 | 65,054 | $2,496 | 192 | - | - | - | - |
$1,691 65,054 kWh |
$2,496 192 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,422 Cost: - |
$817 | 31,434 | $605 | 47 | - | - | - | - |
$817 31,434 kWh |
$605 47 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $487 Cost: - |
- | - | - | - | $487 | 65 | - | - |
- - kWh |
- - kW-months/year |
$487 65 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $569,102 Cost: $132,325 |
$62,945 | 2,379,992 | $33,665 | 2,591 | $213,300 | 28,478 | $259,192 | - | $62,945 2,379,992 kWh |
$33,665 2,591 kW-months/year |
$213,300 28,478 MMBtu |
$259,192 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $39,166 Cost: $3,975 |
$30,361 | 1,167,734 | $8,318 | 636 | $487 | 65 | - | - | $30,361 1,167,734 kWh |
$8,318 636 kW-months/year |
$487 65 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |