Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2006
Principal Product Emergency Medical Vehicles
NAICS 336211 - Motor Vehicle Body Manufacturing
SIC 3713 - Truck And Bus Bodies
Sales $50,000,000-$100,000,000
# of Employees 372
Plant Area (Sq.Ft.) 102,000
Annual Production 471 Pieces
Production Hrs. Annual 7,200
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $71,030 2,435,792 kWh $0.03
Electricity Demand $71,030 4,548 kW-months/year $15.62
Natural Gas $249,097 23,909 MMBtu $10.42
TOTAL ENERGY COSTS $397,069
RECOMMENDED SAVINGS* $492,225 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $450,238
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
01: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$448,000
Cost:
$(-70,000)
- - - - - - $548,000 - - - $(-100,000) - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$548,000
-
$
-
-
$
$(-100,000)
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$10,868
Cost:
$3,600
- - - - $10,868 1,043 - - - - - - -
-
kWh
-
-
kW-months/year
$10,868
1,043
MMBtu
-
-
$
-
-
$
-
-
$
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$9,201
Cost:
-
- - - - $9,201 883 - - - - - - -
-
kWh
-
-
kW-months/year
$9,201
883
MMBtu
-
-
$
-
-
$
-
-
$
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$7,933
Cost:
$1,436
$4,526 151,200 $3,407 252 - - - - - - - - $4,526
151,200
kWh
$3,407
252
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,592
Cost:
$15,876
$2,915 40,484 $682 180 - - - - $(-5) - - - $2,915
40,484
kWh
$682
180
kW-months/year
-
-
MMBtu
-
-
$
$(-5)
-
$
-
-
$
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$3,404
Cost:
-
$1,944 64,800 $1,460 108 - - - - - - - - $1,944
64,800
kWh
$1,460
108
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
07: 2.4237 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING Savings:
$3,177
Cost:
$387
$1,814 60,480 $1,363 101 - - - - - - - - $1,814
60,480
kWh
$1,363
101
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,238
Cost:
$6,552
$1,337 44,554 $1,004 72 - - $(-103) - - - - - $1,337
44,554
kWh
$1,004
72
kW-months/year
-
-
MMBtu
$(-103)
-
$
-
-
$
-
-
$
09: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$2,074
Cost:
-
- - - - $2,074 199 - - - - - - -
-
kWh
-
-
kW-months/year
$2,074
199
MMBtu
-
-
$
-
-
$
-
-
$
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,120
Cost:
-
$1,120 15,552 - - - - - - - - - - $1,120
15,552
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$419
Cost:
$1,968
$419 7,975 - - - - - - - - - - $419
7,975
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
12: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$199
Cost:
-
$69 2,304 $130 12 - - - - - - - - $69
2,304
kWh
$130
12
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$492,225
Cost:
$(-40,181)
$14,144 387,349 $8,046 725 $22,143 2,125 $547,897 - $(-5) - $(-100,000) - $14,144
387,349
kWh
$8,046
725
kW-months/year
$22,143
2,125
MMBtu
$547,897
-
$
$(-5)
-
$
$(-100,000)
-
$
TOTAL IMPLEMENTED Savings:
$450,238
Cost:
$(-63,448)
$1,337 44,554 $1,004 72 - - $547,897 - - - $(-100,000) - $1,337
44,554
kWh
$1,004
72
kW-months/year
-
-
MMBtu
$547,897
-
$
-
-
$
$(-100,000)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost One-time Revenue or Avoided Cost