Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2006 |
Principal Product | Emergency Medical Vehicles |
NAICS | 336211 - Motor Vehicle Body Manufacturing |
SIC | 3713 - Truck And Bus Bodies |
Sales | $50,000,000-$100,000,000 |
# of Employees | 372 |
Plant Area (Sq.Ft.) | 102,000 |
Annual Production | 471 Pieces |
Production Hrs. Annual | 7,200 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $71,030 | 2,435,792 | kWh | $0.03 |
Electricity Demand | $71,030 | 4,548 | kW-months/year | $15.62 |
Natural Gas | $249,097 | 23,909 | MMBtu | $10.42 |
TOTAL ENERGY COSTS | $397,069 | |||
RECOMMENDED SAVINGS* | $492,225 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $450,238 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $448,000 Cost: $(-70,000) |
- | - | - | - | - | - | $548,000 | - | - | - | $(-100,000) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$548,000 - $ |
- - $ |
$(-100,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,868 Cost: $3,600 |
- | - | - | - | $10,868 | 1,043 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,868 1,043 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $9,201 Cost: - |
- | - | - | - | $9,201 | 883 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,201 883 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $7,933 Cost: $1,436 |
$4,526 | 151,200 | $3,407 | 252 | - | - | - | - | - | - | - | - |
$4,526 151,200 kWh |
$3,407 252 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,592 Cost: $15,876 |
$2,915 | 40,484 | $682 | 180 | - | - | - | - | $(-5) | - | - | - |
$2,915 40,484 kWh |
$682 180 kW-months/year |
- - MMBtu |
- - $ |
$(-5) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,404 Cost: - |
$1,944 | 64,800 | $1,460 | 108 | - | - | - | - | - | - | - | - |
$1,944 64,800 kWh |
$1,460 108 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4237 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING |
Savings: $3,177 Cost: $387 |
$1,814 | 60,480 | $1,363 | 101 | - | - | - | - | - | - | - | - |
$1,814 60,480 kWh |
$1,363 101 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,238 Cost: $6,552 |
$1,337 | 44,554 | $1,004 | 72 | - | - | $(-103) | - | - | - | - | - |
$1,337 44,554 kWh |
$1,004 72 kW-months/year |
- - MMBtu |
$(-103) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $2,074 Cost: - |
- | - | - | - | $2,074 | 199 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,074 199 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,120 Cost: - |
$1,120 | 15,552 | - | - | - | - | - | - | - | - | - | - |
$1,120 15,552 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $419 Cost: $1,968 |
$419 | 7,975 | - | - | - | - | - | - | - | - | - | - |
$419 7,975 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $199 Cost: - |
$69 | 2,304 | $130 | 12 | - | - | - | - | - | - | - | - |
$69 2,304 kWh |
$130 12 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $492,225 Cost: $(-40,181) |
$14,144 | 387,349 | $8,046 | 725 | $22,143 | 2,125 | $547,897 | - | $(-5) | - | $(-100,000) | - | $14,144 387,349 kWh |
$8,046 725 kW-months/year |
$22,143 2,125 MMBtu |
$547,897 - $ |
$(-5) - $ |
$(-100,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $450,238 Cost: $(-63,448) |
$1,337 | 44,554 | $1,004 | 72 | - | - | $547,897 | - | - | - | $(-100,000) | - | $1,337 44,554 kWh |
$1,004 72 kW-months/year |
- - MMBtu |
$547,897 - $ |
- - $ |
$(-100,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||