Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2007 |
Principal Product | Bi-Metallic Bushings and Thrust Washers |
NAICS | 336991 - Motorcycle, Bicycle, and Parts Manufacturing |
SIC | 3940 - |
Sales | $50,000,000-$100,000,000 |
# of Employees | 295 |
Plant Area (Sq.Ft.) | 223,740 |
Annual Production | 342,386,767 Pieces |
Production Hrs. Annual | 6,600 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $960,916 | 20,010,558 | kWh | $0.05 |
Natural Gas | $970,112 | 72,998 | MMBtu | $13.29 |
TOTAL ENERGY COSTS | $2,085,626 | |||
RECOMMENDED SAVINGS* | $343,390 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $227,960 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Disposal | Personnel Changes | Administrative Changes | Electricity Usage | Natural Gas | Water Disposal | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $135,639 Cost: $80,000 |
- | - | $135,639 | 10,229 | - | - | - | - | - | - |
- - kWh |
$135,639 10,229 MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $78,829 Cost: - |
- | - | - | - | - | - | - | - | $78,829 | - |
- - kWh |
- - MMBtu |
- - Tgal |
- - $ |
$78,829 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $74,891 Cost: $305,325 |
$69,300 | 1,380,000 | - | - | - | - | $5,591 | - | - | - |
$69,300 1,380,000 kWh |
- - MMBtu |
- - Tgal |
$5,591 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4151 MINIMIZE WATER USAGE |
Savings: $17,430 Cost: $700 |
- | - | $10,300 | 775 | $7,130 | 628,404 | - | - | - | - |
- - kWh |
$10,300 775 MMBtu |
$7,130 628,404 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $15,400 Cost: - |
$15,400 | 308,000 | - | - | - | - | - | - | - | - |
$15,400 308,000 kWh |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $15,104 Cost: $5,930 |
$14,360 | 287,100 | $744 | 56 | - | - | - | - | - | - |
$14,360 287,100 kWh |
$744 56 MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2424 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS |
Savings: $2,977 Cost: $11,246 |
- | - | $2,977 | 224 | - | - | - | - | - | - |
- - kWh |
$2,977 224 MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2514 COVER OPEN TANKS |
Savings: $2,295 Cost: $355 |
- | - | $2,150 | 162 | $145 | 12,718 | - | - | - | - |
- - kWh |
$2,150 162 MMBtu |
$145 12,718 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $825 Cost: $64 |
$825 | 16,500 | - | - | - | - | - | - | - | - |
$825 16,500 kWh |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $343,390 Cost: $403,620 |
$99,885 | 1,991,600 | $151,810 | 11,446 | $7,275 | 641,122 | $5,591 | - | $78,829 | - | $99,885 1,991,600 kWh |
$151,810 11,446 MMBtu |
$7,275 641,122 Tgal |
$5,591 - $ |
$78,829 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $227,960 Cost: $386,025 |
$69,300 | 1,380,000 | $145,939 | 11,004 | $7,130 | 628,404 | $5,591 | - | - | - | $69,300 1,380,000 kWh |
$145,939 11,004 MMBtu |
$7,130 628,404 Tgal |
$5,591 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||