Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2007 |
Principal Product | Farm Machinery |
NAICS | 333111 - Farm Machinery and Equipment Manufacturing |
SIC | 3523 - Farm Machinery And Equipment |
Sales | $1,000,000-$5,000,000 |
# of Employees | 25 |
Plant Area (Sq.Ft.) | 35,000 |
Annual Production | 250,000 Units |
Production Hrs. Annual | 2,250 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $27,727 | 168,440 | kWh | $0.16 |
Natural Gas | $19,944 | 1,756 | MMBtu | $11.36 |
TOTAL ENERGY COSTS | $49,857 | |||
RECOMMENDED SAVINGS* | $25,338 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,712 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $9,128 Cost: $3,450 |
- | - | - | - | $9,128 | 803 | - | - |
- - kWh |
- - kW-months/year |
$9,128 803 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9111 USE SOLAR HEAT TO HEAT MAKE-UP AIR |
Savings: $4,626 Cost: $17,500 |
- | - | - | - | $4,626 | 406 | - | - |
- - kWh |
- - kW-months/year |
$4,626 406 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,922 Cost: $7,945 |
$948 | 20,617 | $1,905 | 8 | - | - | $69 | - |
$948 20,617 kWh |
$1,905 8 kW-months/year |
- - MMBtu |
$69 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,808 Cost: $3,777 |
$829 | 18,023 | $1,666 | 7 | - | - | $313 | - |
$829 18,023 kWh |
$1,666 7 kW-months/year |
- - MMBtu |
$313 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,628 Cost: $915 |
$497 | 10,800 | $1,131 | 5 | - | - | - | - |
$497 10,800 kWh |
$1,131 5 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $997 Cost: - |
$666 | 7,191 | $331 | 3 | - | - | - | - |
$666 7,191 kWh |
$331 3 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $764 Cost: $883 |
$340 | 7,410 | $424 | 2 | - | - | - | - |
$340 7,410 kWh |
$424 2 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7145 INSTALL SKYLIGHTS |
Savings: $666 Cost: $2,421 |
$666 | 14,477 | - | - | - | - | - | - |
$666 14,477 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7311 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE |
Savings: $500 Cost: - |
- | - | - | - | $500 | 44 | - | - |
- - kWh |
- - kW-months/year |
$500 44 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $496 Cost: - |
$25 | 542 | $471 | 2 | - | - | - | - |
$25 542 kWh |
$471 2 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7145 INSTALL SKYLIGHTS |
Savings: $354 Cost: $1,083 |
$354 | 7,692 | - | - | - | - | - | - |
$354 7,692 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $233 Cost: $500 |
$77 | 1,683 | $156 | 1 | - | - | - | - |
$77 1,683 kWh |
$156 1 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $216 Cost: $324 |
$72 | 1,566 | $144 | 1 | - | - | - | - |
$72 1,566 kWh |
$144 1 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,338 Cost: $38,798 |
$4,474 | 90,001 | $6,228 | 29 | $14,254 | 1,253 | $382 | - | $4,474 90,001 kWh |
$6,228 29 kW-months/year |
$14,254 1,253 MMBtu |
$382 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,712 Cost: $21,298 |
$4,474 | 90,001 | $6,228 | 29 | $9,628 | 847 | $382 | - | $4,474 90,001 kWh |
$6,228 29 kW-months/year |
$9,628 847 MMBtu |
$382 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |