Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | University of Dayton |
---|---|
Assessment Year | 2007 |
Principal Product | Wood Office Furniture |
NAICS | 337211 - Wood Office Furniture Manufacturing |
SIC | 2521 - Wood Office Furniture |
Sales | $100,000,000-$500,000,000 |
# of Employees | 707 |
Plant Area (Sq.Ft.) | 1,196,000 |
Annual Production | 260,000 Pieces |
Production Hrs. Annual | 2,450 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $909,559 | 13,647,625 | kWh | $0.07 |
Natural Gas | $631,944 | 64,778 | MMBtu | $9.76 |
TOTAL ENERGY COSTS | $1,541,503 | |||
RECOMMENDED SAVINGS* | $273,822 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $201,771 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.454 MODIFY STARTUP/SHUTDOWN TIMES |
Savings: $144,431 Cost: - |
$7,231 | 109,564 | - | - | - | - | $137,200 | - | - | - |
$7,231 109,564 kWh |
- - kW-months/year |
- - MMBtu |
$137,200 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $37,082 Cost: $161,076 |
$33,617 | 509,355 | $3,465 | 231 | - | - | - | - | - | - |
$33,617 509,355 kWh |
$3,465 231 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7314 REDUCE VENTILATION AIR |
Savings: $19,800 Cost: $1,590 |
$8,659 | 131,198 | $893 | 60 | $10,248 | 1,050 | - | - | - | - |
$8,659 131,198 kWh |
$893 60 kW-months/year |
$10,248 1,050 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7311 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE |
Savings: $14,325 Cost: $3,260 |
$3,218 | 48,755 | - | - | $11,107 | 1,138 | - | - | - | - |
$3,218 48,755 kWh |
- - kW-months/year |
$11,107 1,138 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,452 Cost: $71,033 |
$11,931 | 180,776 | $778 | 52 | - | - | - | - | $743 | - |
$11,931 180,776 kWh |
$778 52 kW-months/year |
- - MMBtu |
- - $ |
$743 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $11,132 Cost: $25,500 |
$10,187 | 154,350 | $945 | 63 | - | - | - | - | - | - |
$10,187 154,350 kWh |
$945 63 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,540 Cost: $58,765 |
$8,033 | 121,716 | $828 | 55 | - | - | - | - | $1,679 | - |
$8,033 121,716 kWh |
$828 55 kW-months/year |
- - MMBtu |
- - $ |
$1,679 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $7,421 Cost: $17,000 |
$6,791 | 102,900 | $630 | 42 | - | - | - | - | - | - |
$6,791 102,900 kWh |
$630 42 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $7,068 Cost: - |
$6,468 | 98,000 | $600 | 40 | - | - | - | - | - | - |
$6,468 98,000 kWh |
$600 40 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $5,744 Cost: $600 |
$5,744 | 87,028 | - | - | - | - | - | - | - | - |
$5,744 87,028 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,297 Cost: $3,275 |
$2,102 | 31,850 | $195 | 13 | - | - | - | - | - | - |
$2,102 31,850 kWh |
$195 13 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $530 Cost: $930 |
$485 | 7,350 | $45 | 3 | - | - | - | - | - | - |
$485 7,350 kWh |
$45 3 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $273,822 Cost: $343,029 |
$104,466 | 1,582,842 | $8,379 | 559 | $21,355 | 2,188 | $137,200 | - | $2,422 | - | $104,466 1,582,842 kWh |
$8,379 559 kW-months/year |
$21,355 2,188 MMBtu |
$137,200 - $ |
$2,422 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $201,771 Cost: $240,116 |
$57,774 | 875,385 | $5,118 | 341 | - | - | $137,200 | - | $1,679 | - | $57,774 875,385 kWh |
$5,118 341 kW-months/year |
- - MMBtu |
$137,200 - $ |
$1,679 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes |