Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2008 |
Principal Product | Folding Cartons |
NAICS | 322212 - Folding Paperboard Box Manufacturing |
SIC | 2657 - Folding Paperboard Boxes |
Sales | $100,000,000-$500,000,000 |
# of Employees | 235 |
Plant Area (Sq.Ft.) | 229,630 |
Annual Production | 105,000,000 Tons |
Production Hrs. Annual | 8,400 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $743,553 | 14,198,362 | kWh | $0.05 |
Natural Gas | $284,925 | 29,868 | MMBtu | $9.54 |
TOTAL ENERGY COSTS | $1,120,442 | |||
RECOMMENDED SAVINGS* | $119,988 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $94,849 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7314 REDUCE VENTILATION AIR |
Savings: $47,843 Cost: $62,700 |
- | - | - | - | - | - | $47,843 | 5,015 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$47,843 5,015 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $35,242 Cost: $107,122 |
$15,120 | 1,008,000 | $15,941 | 120 | - | - | - | - | - | - | $4,181 | - |
$15,120 1,008,000 kWh |
$15,941 120 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$4,181 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $12,341 Cost: $6,560 |
$6,562 | 437,220 | $5,779 | 44 | - | - | - | - | - | - | - | - |
$6,562 437,220 kWh |
$5,779 44 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $9,025 Cost: $2,424 |
- | - | - | - | - | - | $9,025 | 827 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$9,025 827 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $7,098 Cost: $39,000 |
- | - | - | - | $7,098 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,098 - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $2,330 Cost: $300 |
- | - | - | - | - | - | - | - | $2,330 | 593,912 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$2,330 593,912 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,714 Cost: $2,828 |
$553 | 36,855 | $1,161 | 13 | - | - | - | - | - | - | - | - |
$553 36,855 kWh |
$1,161 13 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,656 Cost: - |
$806 | 53,760 | $850 | 6 | - | - | - | - | - | - | - | - |
$806 53,760 kWh |
$850 6 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,351 Cost: $1,000 |
$1,159 | 77,280 | $1,192 | 2 | - | - | - | - | - | - | - | - |
$1,159 77,280 kWh |
$1,192 2 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $388 Cost: $1,000 |
$189 | 12,600 | $199 | 2 | - | - | - | - | - | - | - | - |
$189 12,600 kWh |
$199 2 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $119,988 Cost: $222,934 |
$24,389 | 1,625,715 | $25,122 | 187 | $7,098 | - | $56,868 | 5,842 | $2,330 | 593,912 | $4,181 | - | $24,389 1,625,715 kWh |
$25,122 187 kW-months/year |
$7,098 - $ |
$56,868 5,842 MMBtu |
$2,330 593,912 Tgal |
$4,181 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $94,849 Cost: $174,246 |
$16,468 | 1,097,880 | $17,332 | 124 | - | - | $56,868 | 5,842 | - | - | $4,181 | - | $16,468 1,097,880 kWh |
$17,332 124 kW-months/year |
- - $ |
$56,868 5,842 MMBtu |
- - Tgal |
$4,181 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes |