Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2010 |
Principal Product | Blow molded, injection molded |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 291 |
Plant Area (Sq.Ft.) | 198,000 |
Annual Production | 13,476,977 Pieces |
Production Hrs. Annual | 7,200 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $450,369 | 9,616,440 | kWh | $0.05 |
Electricity Demand | $359,547 | 2,122 | kW-months/year | $169.44 |
Natural Gas | $44,725 | 4,423 | MMBtu | $10.11 |
TOTAL ENERGY COSTS | $872,075 | |||
RECOMMENDED SAVINGS* | $108,424 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $81,880 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,978 Cost: - |
- | - | - | - | $2,978 | - | - | - |
- - kWh |
- - kW-months/year |
$2,978 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,468 Cost: - |
$1,468 | 32,625 | - | - | - | - | - | - |
$1,468 32,625 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $17,881 Cost: - |
$12,131 | 269,568 | $5,750 | 34 | - | - | - | - |
$12,131 269,568 kWh |
$5,750 34 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,929 Cost: - |
$5,853 | 130,062 | $3,076 | 18 | - | - | - | - |
$5,853 130,062 kWh |
$3,076 18 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,108 Cost: - |
$2,693 | 59,836 | $1,415 | 8 | - | - | - | - |
$2,693 59,836 kWh |
$1,415 8 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $22,144 Cost: - |
$14,515 | 322,560 | $7,629 | 45 | - | - | - | - |
$14,515 322,560 kWh |
$7,629 45 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $346 Cost: - |
$227 | 5,040 | $119 | 1 | - | - | - | - |
$227 5,040 kWh |
$119 1 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $6,179 Cost: - |
$4,050 | 90,000 | $2,129 | 13 | - | - | - | - |
$4,050 90,000 kWh |
$2,129 13 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $15,412 Cost: - |
$(-1,073) | (-13,241) | - | - | - | - | $16,485 | 1,624,656 |
$(-1,073) (-13,241) kWh |
- - kW-months/year |
- - $ |
$16,485 1,624,656 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE |
Savings: $3,601 Cost: - |
$3,601 | 80,016 | - | - | - | - | - | - |
$3,601 80,016 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $7,426 Cost: - |
$7,426 | 165 | - | - | - | - | - | - |
$7,426 165 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,512 Cost: - |
$4,512 | 100,271 | - | - | - | - | - | - |
$4,512 100,271 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $1,524 Cost: - |
$1,524 | 33,869 | - | - | - | - | - | - |
$1,524 33,869 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $10,027 Cost: - |
$10,027 | 955 | - | - | - | - | - | - |
$10,027 955 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $1,123 Cost: - |
$1,123 | 107 | - | - | - | - | - | - |
$1,123 107 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $766 Cost: - |
$766 | 73 | - | - | - | - | - | - |
$766 73 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $108,424 Cost: - |
$68,843 | 1,111,906 | $20,118 | 119 | $2,978 | - | $16,485 | 1,624,656 | $68,843 1,111,906 kWh |
$20,118 119 kW-months/year |
$2,978 - $ |
$16,485 1,624,656 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $81,880 Cost: - |
$47,525 | 901,846 | $17,870 | 105 | - | - | $16,485 | 1,624,656 | $47,525 901,846 kWh |
$17,870 105 kW-months/year |
- - $ |
$16,485 1,624,656 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal |